Type Code; Scope Of Delivery; Accessories (Optionally Available); Installation - salmson Rocsan evo Installation Et Mise En Service

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
English
You will find the technical data of freely configu-
rable evo units in the order confirmation.
4.6.

Type code

Salmson-Rocsan
Example:
evo V06DA-110/EAD1X2-T0015-540-O
evo
Series
Impeller shape
V
V = free-flow impeller
Discharge port size
05 = DN 50
06
06 = DN 65/80
08 = DN 80
Hydraulic version
D = intake side drilled according to DIN
D
N = intake side drilled according to North American
Standard (ANSI)
Material type for hydraulics
A = standard type
B = corrosion protection 1
A
C = corrosion protection 2
D = abrasion protection 1
E = abrasion protection 2
X = special type
110
Hydraulics definition
Motor version
E
E = dry motor
R = performance-reduced dry motor
Material type for hydraulics
A = standard type
B = corrosion protection 1
A
C = corrosion protection 2
D = abrasion protection 1
E = abrasion protection 2
X = special type
Seal version
D
D = 2 independent mechanical shaft seals
B = cartridge seal
IE efficiency class, e.g.: 1 = IE1 (based on
1
IEC 60034-30)
X
With ATEX explosion approval
2
Number of poles
Mains supply version
T
M = 1~
T = 3~
0015
/10 = rated motor capacity P
Frequency
5
5 = 50 Hz
6 = 60 Hz
40
Code for rated voltage
Additional electrical equipment
o
O = with free cable end
P = with plug
in kW
2
43
4.7.

Scope of delivery

Standard items
• Unit with 10 m cable
• AC version with capacitor switching device and free cable
end
• Three-phase current version with:
• free cable end
• CEE plug
• Installation and operation manual
Freely configurable items
• Unit with cable length chosen by the customer
• Cable version with:
• free cable end
• plug
• float switch and free cable end
• float switch and plug
• Installation and operation manual
4.8.

Accessories (optionally available)

• Cable lengths up to 50 m in fixed increments of 10 m or
individual cable lengths on request
• Suspension device
• Pump pedestal
• External leak electrode
• Level controllers
• Fixing accessories and chains
• Switching devices, relays and plugs
• Ceram coating
• Thermal motor monitor with PTC sensors
5.

Installation

In order to prevent damage to the product or serious injury during
installation, the following points must be observed:
• Installation work – assembly and installation of the ma-
chine – may only be carried out by qualified persons. The
safety instructions must be followed at all times.
• The machine must be inspected for transport damage
before carrying out any installation work.
5.1.

General requirements

For planning and operation of technical waste water systems,
pay attention to the pertinent local regulations and directives
for wastewater technology (such as the German Association for
Water, Wastewater and Waste).
Pay attention to pressure surges, in particular with stationary
installations where water is pumped with longer discharge pipes
(especially with steady ascents or steep terrain).
Pressure surges can cause irreversible damage to the unit/system
and noisy operation resulting from valve knocking. This can be
avoided by taking appropriate measures (e.g. non-return valves
with adjustable closure time or laying the discharge pipe in a
special way).
After pumping water containing lime, clay or cement, flush out
the product with clean water in order to prevent encrustation and
subsequent breakdowns.