Operation With Frequency Converter; Operation In An Explosive Atmosphere; Technical Data; Type Key - salmson Rocsan neo Installation Et Mise En Service

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
en
perature no longer differs from the temperature of the
coolant by more than 2 K.
Operating mode S3: Intermittent periodic duty
This operating mode defines a switching cycle in a
combination of periods of operation and standstill.
Specified value (e.g. S3 25 %) relates to the operating
time. The switching cycle has a duration of 10 min.
If two values (e.g. S3 25 %/120 s) are specified, the first
value relates to the operating time. The second value
specifies the max. period of the switching cycle.
4.4

Operation with frequency converter

Operation on the frequency converter is not permitted.
4.5

Operation in an explosive atmosphere

Operation in an explosive atmosphere is not permitted.
4.6

Technical data

General
Mains connection [U/f]
See rating plate
Power consumption [P
] See rating plate
1
Rated power [P
]
See rating plate
2
Maximum delivery head
See rating plate
[H]
Max. volume flow [Q]
See rating plate
Activation type [AT]
See rating plate
Fluid temperature [t]
3...40 °C
Protection class
IP68
Insulation class [Cl.]
F
Speed [n]
See rating plate
Max. switching fre-
30/h
quency
Max. immersion depth
See rating plate
[8]
Cable length (standard
10 m
version)
Explosion protection
-
Operating modes
Immersed [OTs]
S1
Non-immersed [OTe]
S2-15, S3 10 %*
Pressure connection
UNI V05...
DN 50, PN 10
UNI V06...
DN 50/65, PN 10
* Operating mode S3 25 % is permitted if the necessary
motor cooling is guaranteed before the motor is
switched on again! To ensure the required cooling, the
motor must be completely immersed for at least 1 min.!
38

Transportation and storage

4.7

Type key

Example: Salmson Rocsan neo V05/T06-540/P
neo
Series
V
Impeller = vortex impeller
05
Nominal diameter of pressure connection
T
Mains connection version: M = 1~, T = 3~
06
/10 = Rated power P
2
5
Frequency mains connection: 5 = 50 Hz, 6 = 60 Hz
40
Code for rated voltage
Additional electrical equipment:
without = with free cable end
P
A = with float switch and plug
P = with plug
4.8

Scope of delivery

▪ Pump with 10 m cable
▪ Single-phase version with
– Shockproof plug
– Float switch and shockproof plug
▪ Three-phase version with
– Bare cable end
– Float switch and CEE plug
▪ Installation and operating instructions
4.9

Accessories

▪ Cable lengths in fixed length increments of 10 m to
max. 30 m in the single-phase current version or max.
50 m in the three-phase version
▪ Suspension unit
▪ Level control devices
▪ Fixation accessories and chains
▪ Switchgear, relays and plugs
5
Transportation and storage
5.1

Delivery

After receiving the shipment, this must be checked im-
mediately for defects (damage, completeness). Defects
must be noted on the freight documentation! Further-
more, defects must be notified to the transport com-
pany or the manufacturer immediately on the day of
receipt of shipment. Subsequently notified defects can
no longer be asserted.
5.2

Transport

WARNING
Standing beneath suspended loads!
Never allow anyone to stand under suspended loads!
Danger of (serious) injuries caused by falling parts.
Loads may not be carried over work places where
people are present!
in kW