PREVOST X3-45 Manuel De L'opérateur page 212

Masquer les pouces Voir aussi pour X3-45:
Table des Matières

Publicité

206
Annexe C – Codes d'anomalie de la transmission Allison
DTC
P071D General Purpose Input Fault
P0720
Output Speed Sensor Circuit
P0721
Output Speed Sensor Circuit Performance
P0722
Output Speed Sensor Circuit No Signal
P0726
Engine Speed Sensor Circuit Performance
P0727
Engine Speed Sensor Circuit No Signal
th
P0729
Incorrect 6
Gear Ratio
P0730
Incorrect Neutral Gear ratio
st
P0731
Incorrect 1
Gear ratio
nd
P0732
Incorrect 2
Gear ratio
rd
P0733
Incorrect 3
Gear ratio
th
P0734
Incorrect 4
Gear ratio
th
P0735
Incorrect 5
Gear ratio
P0736
Incorrect Reverse Gear ratio
P0741
Torque Converter Clutch System Stuck Off
P0776
Pressure Control Solenoid 2 Stuck Off
P0777
Pressure Control Solenoid 2 Stuck On
P0796
Pressure Control Solenoid 3 Stuck Off
P0797
Pressure Control Solenoid 3 Stuck On
P0842
Transmission Pressure Switch 1 Circuit Low
P0843
Transmission Pressure Switch 1 Circuit High
P0847
Transmission Pressure Switch 2 Circuit Low
P0848
Transmission Pressure Switch 2 Circuit High
P088A Transmission Fluid Filter Deteriorated
P088B Transmission Fluid Filter Very Deteriorated
P0880
TCM Power Input Signal
P0881
TCM Power Input Signal Performance
P0882
TCM Power Input Signal Low
P0883
TCM Power Input Signal High
P0894
Transmission Component Slipping
P0960
Pressure Control Solenoid Main Mod Control Circuit Open
Pressure Control Solenoid (PCS) MM System
P0961
Performance
P0962
Pressure Control Solenoid Main Mod Control Circuit Low
P0963
Pressure Control Solenoid Main Mod Control Circuit High
P0964
Pressure Control Solenoid 2 (PCS2) Control Circuit Open
P0965
Pressure Control Solenoid (PCS) 2 System Performance
P0966
Pressure Control Solenoid 2 (PCS2) Control Circuit Low
P0967
Pressure Control Solenoid 2 (PCS2) Control Circuit High
P0968
Pressure Control Solenoid 3 (PCS3) Control Circuit Open
P0969
Pressure Control Solenoid (PCS) 3 System Performance
P0970
Pressure Control Solenoid 3 (PCS3) Control Circuit Low
P0971
Pressure Control Solenoid 3 (PCS3) Control Circuit High
P0973
Shift Solenoid 1 (SS1) Control Circuit Low
Description
CHECK
Inhibited Operation
TRANS
Description
Light
Yes
None
Yes
DNS, Lock in current range
Yes
DNS, Lock in current range
No
Default to turbine speed
No
Default to turbine speed
Yes
DNS, Attempt 5
Yes
DNS, Attempt 2
Yes
DNS, Attempt 3
Yes
DNS, Attempt 4
Yes
DNS, Attempt 5
Yes
DNS, Attempt 6
Yes
DNS, Lock in Neutral
Yes
None
Yes
DNS, RPR
Yes
DNS, RPR
Yes
DNS, RPR
Yes
DNS, RPR
Yes
DNS, Lock in current range
Yes
DNS, Lock in current range
No
None
No
None
Yes
DNS, SOL OFF (hydraulic default)
No
None
Yes
DNS, Lock in first
Yes
None
Yes
DNS, SOL OFF (hydraulic default)
Yes
None
Yes
DNS, SOL OFF (hydraulic default)
Yes
DNS, SOL OFF (hydraulic default)
Yes
DNS, SOL OFF (hydraulic default)
Yes
DNS, SOL OFF (hydraulic default)
Yes
DNS, SOL OFF (hydraulic default)
Yes
DNS, SOL OFF (hydraulic default)
Yes
DNS, SOL OFF (hydraulic default)
th
rd
, then 3
nd
th
, then 5
rd
th
, then 5
th
th
, then 6
th
rd
, then 3
th
rd
nd
, then 3
, then 2

Publicité

Table des Matières
loading

Table des Matières