Parker 690 Série Manuel D'installation page 151

Table des Matières

Publicité

Logic Func 1
OUTPUT [183] –
Run DIN1 (previous sheet)
(5)
FALSE
– [180] INPUT A
Ready (previous sheet)
(11)
FALSE
– [181] INPUT B
TRUE – [182] INPUT C
AND (A,B,C) – [184] TYPE
Line Speed ANIN1 (previous sheet)
Feedbacks
DC LINK VOLTS
[ 75] – 0 V
TERMINAL VOLTS
[1020] – 0 V
– SPEED FEEDBACK RPM
[569] – 0.00 rpm
SPEED FEEDBACK HZ
[568] – 0.00 Hz
SPEED FEEDBACK %
[749] –
0.00 %
ENCODER COUNT
[1016] – 0
TORQUE FEEDBACK
[ 71] – 0.00 %
FIELD FEEDBACK
[ 73] – 0.00 %
MOTOR CURRENT %
[ 66] – 0.00 %
MOTOR CURRENT
[ 67] – 0.0 A
10.0 V – [761] ENCODER SUPPLY
** 2048 – [566] ENCODER LINES
FALSE – [567] ENCODER INVERT
FALSE –
[ 50] QUADRATIC TORQUE
Logic Func 2
OUTPUT [188] –
FALSE
FALSE – [185] INPUT A
FALSE – [186] INPUT B
FALSE – [187] INPUT C
OR (A,B,C) – [189] TYPE
Input A is used to provide
a boolean for the operator
menu (LOAD CELL FBK).
Macro 4: Enrouleur piloté en vitesse (SPW)
690+ Series Frequency Inverter
(27)
FALSE
Diameter Calc
CURRENT CORE [834] –
10.00 %
DIAMETER [835] –
10.00 %
MOD LINE SPEED [836] – 0.00 %
– MOD REEL SPEED
[837] –
0.00 %
FALSE – [821] DIAMETER HOLD
FALSE – [822] PRESET ENABLE
FALSE – [823] SELECT CORE 2
FALSE – [824] SEL EXT DIAMETER –
(21)
FALSE
– [825] TENSION ENABLE
10.00 % – [826] CORE 1
10.00 % – [827] CORE 2
5.00 s – [828] DIAMETER TC
0.00 % – [829] EXT DIAMETER
(1)
0.00 %
– [830] LINE SPEED
10.00 % – [831] MINIMUM DIAMETER –
5.00 % – [832] MINIMUM SPEED
(34)
0.00 %
– [833] REEL SPEED
(23)
(24)
10.00 %
1.000 s – [846] TENSION RAMP
Taper Spt ANIN4 (previous sheet)
(16)
Tension Spt ANIN3 (previous sheet)
(15)
10.00 % – [805] DIAMETER
10.00 % – [806] MINIMUM DIAMETER –
0.00 % – [807] VARIABLE INERTIA
0.00 % – [808] FIXED INERTIA
0.00 % – [809] WIDTH
FALSE – [810] UNWIND
0.00 % – [811] LINE SPD DEMAND
0.00 % – [812] RATE CAL
FALSE – [813] REVERSE
Diameter ANOUT2 (previous sheet)
(19)
0.00 % – [814] DYNAMIC COMP
0.00 % – [815] STATIC COMP
0.00 % – [816] MOD REEL SPEED
Speed Calc
SPEED DEMAND
UP TO SPD (UTS)
FALSE – [774] UNWIND
FALSE – [775] OVER-WIND
FALSE – [776] OVER SPD ENABLE
5.00 % – [777] UTS THRESHOLD
(27)
0.00 %
– [778] LINE SPEED
(26)
0.00 %
– [779] MOD REEL SPEED
(25)
10.00 %
– [780] DIAMETER
(28)
10.00 %
– [781] MINIMUM DIAMETER
0.00 % – [782] OVER SPEED
0.00 % – [783] SPEED TRIM
Feedback ANIN2 (previous sheet)
Taper Calc
TAPERED DEMAND [850] – 0.00 %
TENSION DEMAND [851] –
0.00 %
FALSE – [838] HYPERBOLIC TAPER –
FALSE – [839] STALL ENABLE
FALSE – [840] BOOST ENABLE
FALSE – [841] FIXED BOOST
FALSE – [842] FIXED STALL TEN
0.00 %
– [843] CURRENT CORE
– [844] DIAMETER
0.00 % – [845] BOOST
0.00 % – [847] STALL TENSION
0.00 %
– [848] TAPER SPT
0.00 %
– [849] TENSION SPT
Torque Calc
Compensation
POS TORQUE LIMIT [790] – 200.00 %
COMPENSATIONS [817] – 0.00 %
NEG TORQUE LIMIT [791] – -200.00 %
INERTIA COMP [818] – 0.00 %
FALSE – [786] OVER-WIND
SCALED RATE [819] – 0.00 %
FALSE – [787] TENSION ENABLE
LINE SPEED RATE [820] – 0.00 %
0.00 % – [788] TENSION DEMAND
200.00 % – [789] TORQUE LIMIT
Value Func 1
OUTPUT [133] –
[784] –
0.00 %
(32)
0.00
– [130] INPUT A
[785] – TRUE
0.00
– [131] INPUT B
0.00 – [132] INPUT C
A+B+C – [134] TYPE
PID
PID OUTPUT [320] –
PID ERROR [766] – 0.00 %
0.00 %
– [310] SETPOINT
(3)
0.00%
– [764] FEEDBACK
FALSE – [763] SETPOINT NEGATE
FALSE – [765] FEEDBACK NEGATE –
(27)
FALSE
– [311] ENABLE
FALSE – [312] INTEGRAL DEFEAT
1.0 – [313] P GAIN
1.00 s – [314] I TIME CONST
0.000 s – [315] D TIME CONST
2.000 s – [316] FILTER TC
20.00 % – [317] OUTPUT POS LIMIT
-20.00 % – [318] OUTPUT NEG LIMIT
1.0000 – [319] OUTPUT SCALING
Value Func 2
OUTPUT [138] –
– [135]
INPUT A
0.00
(30)
0.00
– [136]
INPUT B
(29)
0.00
– [137]
INPUT C
SWITCH (A,B)
– [139]
TYPE
11-10
Les Macros
0.00
(14)
Speed Demand (previous sheet)
0.00 %
(33)
(31)
0.00
Tension Dancer Spt. ANOUT3 (previous sheet)

Publicité

Table des Matières
loading

Table des Matières