Analog Input 1
VALUE
[ 16] –
0.00 %
BREAK
[ 18] –
FALSE
100.00 % – [ 14] SCALE
(1)
0.00 %
– [310] SETPOINT
0.00 % – [ 15] OFFSET
(3)
0.00%
– [764] FEEDBACK
0..+10 V – [ 13] TYPE
FALSE – [763] SETPOINT NEGATE
FALSE – [ 12] BREAK ENABLE
0.00 % – [ 17] BREAK VALUE
FALSE – [765] FEEDBACK NEGATE –
(10)
FALSE
– [311] ENABLE
Analog Input 2
FALSE – [312] INTEGRAL DEFEAT
VALUE
[ 25] –
0.00 %
1.0 – [313] P GAIN
BREAK
[ 27] –
FALSE
100.00 % – [ 23] SCALE
1.00 s – [314] I TIME CONST
0.00 % – [ 24] OFFSET
0.000 s – [315] D TIME CONST
0..+10 V – [ 22] TYPE
2.000 s – [316] FILTER TC
FALSE – [ 21] BREAK ENABLE
100.00 % – [317] OUTPUT POS LIMIT
0.00 % – [ 26] BREAK VALUE
-100.00 % – [318] OUTPUT NEG LIMIT
1.0000 – [319] OUTPUT SCALING
Digital Input 1
VALUE [ 31] –
FALSE
FALSE – [ 30]
INVERT
Digital Input 2
VALUE
[ 34] –
FALSE
FALSE – [ 33]
INVERT
Digital Input 3
VALUE [ 37] –
FALSE
FALSE – [ 36]
INVERT
Digital Input 4
VALUE
[ 40] –
FALSE
FALSE – [ 39]
INVERT
Digital Input 5
VALUE [ 43] –
FALSE
FALSE – [ 42]
INVERT
Digital Input 6
VALUE [726] –
FALSE
FALSE – [725] INVERT
Digital Input 7
VALUE [728] –
FALSE
FALSE – [727] INVERT
690+ Series Frequency Inverter
PID
PID OUTPUT [320] –
0.00 %
PID ERROR [766] – 0.00 %
I/O Trips
THERMIST
[1155] – FALSE
ENCODER TB
[1156] – FALSE
EXTERNAL
[234] – FALSE
FALSE –
[760] INVERT THERMIST
FALSE – [1154] INVERT ENC TRIP
(2)
FALSE
[235] INPUT 1 BREAK
(4)
FALSE
[236] INPUT 2 BREAK
Trips Status
ACTIVE TRIPS
[ 4] – 0000
ACTIVE TRIPS+ [740] – 0000
WARNINGS
[ 5] – 0000
WARNINGS+ [741] – 0000
FIRST TRIP
[ 6] – NONE
0000 – [231] DISABLED TRIPS
0040 – [742] DISABLED TRIPS+
Sequencing Logic
TRIPPED
[289] –
RUNNING
[285] –
JOGGING
[302] – FALSE
STOPPING
[303] – FALSE
– OUTPUT CONTACTOR
[286] – FALSE
SWITCH ON ENABLE
[288] – FALSE
SWITCHED ON
[306] – FALSE
READY
[287] – FALSE
SYSTEM RESET
[305] – FALSE
SEQUENCER STATE
[301] – START ENABLED
REMOTE REV OUT
[296] –
HEALTHY
[274] – TRUE
(5)
FALSE
– [291] RUN FORWARD
(6)
FALSE
– [292] RUN REVERSE
(7)
FALSE
– [293] NOT STOP
(9)
FALSE
– [280] JOG
TRUE – [1235] CONTACTOR CLOSED –
TRUE – [276] DRIVE ENABLE
TRUE – [277] NOT FAST STOP
TRUE – [278] NOT COAST STOP
(8)
FALSE
– [294] REMOTE REVERSE
(11)
FALSE
– [282] REM TRIP RESET
TRUE – [290] TRIP RST BY RUN
FALSE – [283] POWER UP START
Minimum Speed
OUTPUT [335] –
0.00 %
(12)
0.00 %
– [336] INPUT
-100.00 % – [337] MINIMUM
PROP. W/MIN. – [338] MODE
(16)
FALSE
FALSE
FALSE
Analog Input 3
VALUE
[715] – 0.00 %
BREAK
[717] – FALSE
100.00 % – [713] SCALE
0.00 % – [714] OFFSET
0..+10 V – [712] TYPE
FALSE – [711] BREAK ENABLE
0.00 % – [716] BREAK VALUE
Reference
SPEED DEMAND [255] –
0.00 %
SPEED SETPOINT [254] – 0.00 %
REVERSE [256] – FALSE
LOCAL SETPOINT [247] – 0.00 %
LOCAL REVERSE [250] – FALSE
COMMS SETPOINT [269] – 0.00 %
(13)
0.00 %
– [245] REMOTE SETPOINT
0.00 % – [248] SPEED TRIM
100.00 % – [252] MAX SPEED CLAMP
-100.00 % – [253] MIN SPEED CLAMP
FALSE – [243] TRIM IN LOCAL
FALSE
– [249] REMOTE REVERSE
Reference Ramp
RAMPING
[698] – FALSE
LINEAR –
[244] RAMP TYPE
10.0 s –
[258] ACCEL TIME
10.0 s –
[259] DECEL TIME
FALSE
[268] SYMMETRIC MODE
10.0 s –
[267] SYMMETRIC TIME
10.00 /s^2 –
[692] SRAMP ACCEL
10.00 /s^2 –
[693] SRAMP DECEL
10.00 /s^3 –
[694] SRAMP JERK 1
10.00 /s^3 –
[695] SRAMP JERK 2
10.00 /s^3 –
[696] SRAMP JERK 3
10.00 /s^3 –
[697] SRAMP JERK 4
FALSE
[691] SRAMP CONTINUOUS
FALSE
[260] HOLD
Reference Stop
RAMPED – [279] RUN STOP MODE
10.0 s – [263] STOP TIME
0.10 % – [266] STOP ZERO SPEED
0.500 s – [284] STOP DELAY
RAMPED – [304] FAST STOP MODE
30.0 s – [275] FAST STOP LIMIT
0.1 s – [264] FAST STOP TIME
1200 Hz/s – [126] FINAL STOP RATE
Reference Jog
10.00 % – [246] SETPOINT
1.0 s – [261] ACCEL TIME
1.0 s – [262] DECEL TIME
Analog Input 4
VALUE [722] – 0.00 %
BREAK [724] – FALSE
100.00 % – [720] SCALE
0.00 % – [721] OFFSET
0..+10 V – [719] TYPE
FALSE – [718] BREAK ENABLE
0.00 % – [723] BREAK VALUE
11-7
Les Macros
Analog Output 1
(17)
0.00 %
– [ 45] VALUE
100.00 % – [ 46] SCALE
0.00 % – [ 47] OFFSET
FALSE – [ 48] ABSOLUTE
0..+10 V – [ 49] TYPE
Setpoint Scale
OUTPUT
[ 59] – 0.0 Hz
(18)
0.00 %
[ 58] INPUT
1500 RPM – [1032] MAX SPEED
Analog Output 2
0.00 % – [731] VALUE
100.00 % – [732] SCALE
0.00 % – [733] OFFSET
FALSE – [734] ABSOLUTE
-10 .. +10 V
– [735] TYPE
Analog Output 3
0.00 % – [800] VALUE
100.00 % – [801] SCALE
0.00 % – [802] OFFSET
FALSE – [803] ABSOLUTE
-10 .. +10 V
– [804] TYPE
Digital Output
1
(14)
FALSE
– [ 52]
VALUE
TRUE – [ 51]
INVERT
Digital Output
2
(15)
FALSE
– [ 55]
VALUE
FALSE – [ 54]
INVERT
Digital Output 3
FALSE – [737] VALUE
FALSE – [736] INVERT
Macro 3: PID