Analog Input 1
–
VALUE
[ 16] –
0.00 %
–
BREAK
[ 18] – FALSE
100.00 % – [ 14] SCALE
–
0.00 % – [ 15] OFFSET
–
-10 .. 10 V
– [ 13] TYPE
–
FALSE – [ 12] BREAK ENABLE
–
0.00 % – [ 17] BREAK VALUE
–
Analog Input 2
–
VALUE
[ 25] –
0.00 %
–
BREAK
[ 27] –
FALSE
100.00 % – [ 23] SCALE
–
0.00 % – [ 24] OFFSET
–
-10 .. 10 V
– [ 22] TYPE
–
FALSE – [ 21] BREAK ENABLE
–
0.00 % – [ 26] BREAK VALUE
–
Analog Input 3
–
VALUE
[715] –
0.00 %
–
BREAK
[717] –
FALSE
100.00 % – [713] SCALE
–
0.00 % – [714] OFFSET
–
-10 .. 10 V – [712] TYPE
–
FALSE – [711] BREAK ENABLE
–
0.00 % – [716] BREAK VALUE
–
Digital Input 1
VALUE [ 31] –
FALSE
(5)
FALSE – [ 30]
INVERT
–
Digital Input 2
(6)
VALUE
[ 34] –
FALSE
FALSE – [ 33]
INVERT
–
Digital Input 3
(7)
VALUE [ 37] –
FALSE
FALSE – [ 36]
INVERT
–
Digital Input 4
VALUE
[ 40] –
FALSE
(19)
FALSE – [ 39]
INVERT
–
Digital Input 5
VALUE [ 43] –
FALSE
(9)
FALSE – [ 42]
INVERT
–
Digital Input 6
(8)
VALUE [726] –
FALSE
FALSE – [725] INVERT
–
Digital Input 7
VALUE [728] –
FALSE
(10)
FALSE – [727] INVERT
–
Digital Input 8 = COAST STOP
690+ Series Frequency Inverter
Value Func 1
(11)
OUTPUT [133] –
0.00 %
(3)
0.00 %
– [130] INPUT A
–
(2)
0.00 %
– [131] INPUT B
–
0.00 – [132] INPUT C
–
A+B+C – [134] TYPE
–
I/O Trips
–
THERMIST
[1155] – FALSE
–
ENCODER TB
[1156] – FALSE
–
EXTERNAL
[234] – FALSE
FALSE –
[760] INVERT THERMIST
–
FALSE – [1154] INVERT ENC TRIP
–
COAST –
[233] EXT TRIP MODE
–
(1)
FALSE
–
[235] INPUT 1 BREAK
–
(4)
FALSE
–
[236] INPUT 2 BREAK
–
Trips Status
ACTIVE TRIPS
[ 4] – 0000
ACTIVE TRIPS+ [740] – 0000
WARNINGS
[ 5] – 0000
WARNINGS+ [741] – 0000
FIRST TRIP
[ 6] – NONE
0600 – [231] DISABLED TRIPS
–
0040 – [742] DISABLED TRIPS+
–
Sequencing Logic
–
TRIPPED
[289] –
FALSE
–
RUNNING
[285] – FALSE
–
JOGGING
[302] – FALSE
–
STOPPING
[303] – FALSE
– OUTPUT CONTACTOR
[286] –
FALSE
–
SWITCH ON ENABLE
[288] – FALSE
–
SWITCHED ON
[306] – FALSE
–
READY
[287] – FALSE
–
SYSTEM RESET
[305] – FALSE
–
SEQUENCER STATE
[301] – START ENABLED
–
REMOTE REV OUT
[296] –
FALSE
–
HEALTHY
[274] – TRUE
FALSE
– [291] RUN FORWARD
–
FALSE
– [292] RUN REVERSE
–
FALSE
– [293] NOT STOP
–
FALSE
– [280] JOG
–
TRUE – [1235] CONTACTOR CLOSED –
TRUE
– [276] DRIVE ENABLE
–
TRUE
– [277] NOT FAST STOP
–
TRUE – [278] NOT COAST STOP
–
FALSE
– [294] REMOTE REVERSE
–
FALSE – [282] REM TRIP RESET
–
TRUE – [290] TRIP RST BY RUN
–
FALSE – [283] POWER UP START
–
Reference
SPEED DEMAND [255] –
0.00 %
SPEED SETPOINT [254] – 0.00 %
REVERSE [256] – FALSE
LOCAL SETPOINT [247] – 0.00 %
LOCAL REVERSE [250] – FALSE
COMMS SETPOINT [770] – 0.00 %
(12)
0.00 %
– [245] REMOTE SETPOINT –
0.00 %
– [248] SPEED TRIM
–
110.00 % – [252] MAX SPEED CLAMP –
-110.00 % – [253] MIN SPEED CLAMP
–
FALSE – [243] TRIM IN LOCAL
–
SENSORLESS VEC – [1157]
(16)
FALSE
– [249] REMOTE REVERSE
–
** 5.50 kW – [1158]
** 50.0 Hz – [1159]
Reference Ramp
** 400.0 V – [1160]
–
RAMPING
[698] – FALSE
** 11.30 A – [ 64]
LINEAR –
[244] RAMP TYPE
–
** 3.39 A – [ 65]
10.0 s –
[258] ACCEL TIME
–
** 1445.0 rpm – [ 83]
10.0 s –
[259] DECEL TIME
–
** STAR – [124]
FALSE –
[268] SYMMETRIC MODE
–
** 4 – [ 84]
10.0 s –
[267] SYMMETRIC TIME
–
10.00 /s^2 –
[692] SRAMP ACCEL
–
** 0.90 – [242]
10.00 /s^2 –
[693] SRAMP DECEL
–
** 2.0 – [1164]
10.00 /s^3 –
[694] SRAMP JERK 1
–
** 1.3625 Ohm – [119]
10.00 /s^3 –
[695] SRAMP JERK 2
–
** 43.37 mH – [120]
10.00 /s^3 –
[696] SRAMP JERK 3
–
** 173.48 mH – [121]
10.00 /s^3 –
[697] SRAMP JERK 4
–
TRUE
–
[691] SRAMP CONTINUOUS
–
276.04 ms – [1163]
FALSE –
[260] HOLD
–
Reference Stop
RAMPED – [279] RUN STOP MODE
–
10.0 s – [263] STOP TIME
–
0.10 % – [266] STOP ZERO SPEED
–
0.500 s – [284] STOP DELAY
–
RAMPED – [304] FAST STOP MODE
–
30.0 s – [275] FAST STOP LIMIT
–
0.1 s – [264] FAST STOP TIME
–
1200 Hz/s – [126] FINAL STOP RATE
–
10.0 V – [761] ENCODER SUPPLY
Reference Jog
** 2048 – [566] ENCODER LINES
10.00 % – [246] SETPOINT
–
FALSE – [567] ENCODER INVERT
1.0 s – [261] ACCEL TIME
–
FALSE –
1.0 s – [262] DECEL TIME
–
0.00 % – [359] HYSTERISIS
0.00 % – [357] THRESHOLD
Analog Input 4
–
VALUE [722] – 0.00 %
–
BREAK [724] – FALSE
100.00 % – [720] SCALE
–
0.00 % – [721] OFFSET
–
0..+10 V – [719] TYPE
–
FALSE – [718] BREAK ENABLE
–
0.00 % – [723] BREAK VALUE
–
Les Macros
(21)
0.00 %
– [ 45] VALUE
100.00 % – [ 46] SCALE
0.00 % – [ 47] OFFSET
TRUE – [ 48] ABSOLUTE
0..+10 V – [ 49] TYPE
–
(18)
0.00 %
–
1500 RPM – [1032] MAX SPEED
Motor Data
CONTROL MODE
–
POWER
–
BASE FREQUENCY
–
MOTOR VOLTAGE
–
MOTOR CURRENT
–
MAG CURRENT
–
NAMEPLATE RPM
–
MOTOR CONNECTION –
MOTOR POLES
–
POWER FACTOR
–
OVERLOAD
–
STATOR RES
–
LEAKAGE INDUC
–
MUTUAL INDUC
–
ROTOR TIME CONST
–
Feedbacks
–
DC LINK VOLTS
[ 75] – 0 V
0.00 %
– [731] VALUE
–
TERMINAL VOLTS
[1020] – 0 V
100.00 % – [732] SCALE
– SPEED FEEDBACK RPM
[569] – 0.00 rpm
0.00 % – [733] OFFSET
–
SPEED FEEDBACK HZ
[568] – 0.00 Hz
FALSE – [734] ABSOLUTE
–
SPEED FEEDBACK %
[749] –
0.00 %
(17)
-10 .. +10 V
– [735] TYPE
–
ENCODER FBK %
[1238] – 0.00 %
–
ENCODER COUNT
[1016] – 0
–
TORQUE FEEDBACK
[ 70] –
0.00 %
(20)
–
FIELD FEEDBACK
[ 73] – 0.00 %
0.00 %
– [800] VALUE
–
MOTOR CURRENT %
[ 66] – 0.00 %
100.00 % – [801] SCALE
–
MOTOR CURRENT
[ 67] – 0.0 A
0.00 % – [802] OFFSET
–
FALSE – [803] ABSOLUTE
–
-10 .. +10 V
– [804] TYPE
–
[ 50] QUADRATIC TORQUE
–
(13)
FALSE
– [ 52]
TRUE – [ 51]
Zero Speed
–
AT ZERO SPD FBK [1233] –
TRUE
–
AT ZERO SPD DMD
[360] – TRUE
–
AT STANDSTILL [1234] – TRUE
–
(15)
FALSE
– [ 55]
–
FALSE – [ 54]
(14)
FALSE
– [737] VALUE
FALSE – [736] INVERT
Macro 6: Variateur "Système"
11-14
Analog Output 1
–
–
–
–
–
Setpoint Scale
OUTPUT [ 59] – 0.0 Hz
[ 58] INPUT
–
–
Analog Output 2
–
–
–
–
–
Analog Output 3
–
–
–
–
–
Digital Output 1
VALUE
–
INVERT
–
Digital Output 2
VALUE
–
INVERT
–
Digital Output 3
–
–