1.6 Connecting to the 230V power supply
• For your safety, these operations must be
carried out with the power supply switched off.
• Use a 3 x 1.5 mm² cable or 3 x 2.5 mm² for
outdoor use (type H07RN-F minimum).
1.
Strip the wire over a distance of
150 mm.
2.
Overlap the live and neutral wires
at 100 mm.
3.
Strip the 3 wires over a distance of
8 mm.
4.
Crimp the terminal provided
on the earth wire (yellow and
green).
6.
Connect the wires as shown in the
table:
Wire
Type
colour
Blue
Neutral 17
Brown /
Live
black / red
Yellow and
Earth
green
7.
Tighten the cable clamp supplied.
For a 3x1.5 mm² cable
Terminal Comments
16
Tighten a flat
washer
,
the
power supply earth
terminal crimped
in step 4 and a star
washer
using a
screw
.
• The cable clamp supplied must be used.
For all low-voltage cables, ensure that
they can withstand traction of 100 N.
Check that the conductors have not moved
when this traction has been applied.
100 mm
8 mm
150 mm
Neutral
For a 3x2.5 mm² cable
EN - FREEVIA LINE installation and operating guide - SOMFY
Installation
Neutral
Live
Live
1
13