ENS 3000
8.5
SETTING RANGES FOR THE WINDOW FUNCTION
Probe length
in cm
25.0
41.0
52.0
73.0
The increment for all units is 0.1 cm.
Probe length
in inch *
9.80
16.20
20.50
28.70
The increment for all units is 0.05 inch
8.6
SETTING RANGES FOR THE OFFSET
Probe length
in cm
25
41
52
73
The increment for all units is 0.1 cm.
Probe length
in inch
9.8
16.2
20.5
28.7
The increment for all units is 0.05 inch.
* All ranges given in the table can be adjusted by the increments shown.
Status 19.09.2018
Lower switch value
in cm *
0.3 .. 16.7
0.5 .. 28.4
0.6 . 38.3
0.9 .. 57.9
Lower switch value
in inch *
0.10 .. 6.55
0.20 .. 11.15
0.25 . 15.05
0.40 .. 22.80
Measuring range
in cm
17
29
39
59
Measuring range
in inch
6.7
11.4
15.35
23.2
HYDAC ELECTRONIC GMBH
Upper switch value
in cm*
0.4.. 16.8
0.7 .. 28.7
0.9 .. 38.6
1.4 .. 58.4
Upper switch value
in inch *
0.20 .. 6.60
0.30 .. 11.25
0.35 .. 15.15
0.60 .. 23.00
Setting range for
Offset in cm *
0 .. 68
0 .. 116
0 .. 156
0 .. 177
Setting range for
Offset in inch*
0 .. 26.8
0 .. 45.6
0 .. 61.4
0 .. 69.6
Page16
Part No. 669849