5.2. analogue output

analogue output signal:
5.3. setting tHe switcHing points, Hystereses and/or
E
switcHing values for tHe window function
 press "mode" key.
 "S.P.1" or "hi.1" is displayed.
 keep pressing the "mode" key until the required parameter is displayed (for
pre-set switching point function: "S.P.1", "hYS.1", "S.P.2", "hYS.2" appears;
for pre-set window function (win) "Hi.1", "Lo.1", "Hi.2" or "Lo.2" is shown).
 After 2 seconds the actual setting flashes.
 use the  or the  keys to alter the setting.
 use the "mode" key to call up other parameters, if required, and alter the
setting using the  and the  keys.
 if no keys are pressed for 3 seconds, the display changes back and the
settings are saved.
display
keep pressing "mode"
key until the required
parameter is displayed.
nOTES:
 if "LOc" appears in the display when trying to alter the settings,
programming is disabled.
corrective action: set programming enable(s) to "FREE" .
(see point 7 "programming enables")
 if the  or the  key is held down during alteration, the value automatically
advances.
 if a setting has been altered, "PROG" appears briefly in the display when the
display is switched over. the new setting is then saved in the unit.
36
4 .. 20 mA or 0 .. 10 V
(can be set in the menu "basic settings").
actual
switching
point 1
setting the switching point
= value decreases
= value increases
5.4. setting ranges for switcHing outputs
measuring range switching point
in bar
in bar
-1
..
1
- 0.97
..
1.00
0
..
1
0.016 .. 1.000
0
.. 2.5
0.040 .. 2.500
0
..
6
0.09
..
6.00
0
..
10
0.16
.. 10.00
0
..
16
0.25
.. 16.00
0
..
40
0.6
..
40.0
0
.. 100
1.6
.. 100.0
0
.. 250
4.0
.. 250.0
0
.. 400
6
..
400
0
.. 600
9
..
600
measuring range lower switching value upper switching value increment*
in bar
in bar
-1
..
1
- 0.97
..
0.96
0
..
1
0.016 .. 0.982
0
.. 2.5
0.040 .. 2.455
0
..
6
0.09
..
5.89
0
..
10
0.16
..
9.82
0
..
16
0.25
.. 15.70
0
..
40
0.6
..
39.2
0
.. 100
1.6
..
98.2
0
.. 250
4.0
.. 245.5
0
.. 400
6
..
392
0
.. 600
9
..
589
* all ranges given in the table are adjustable by the increments shown.
Hysteresis
increment*
in bar
in bar
-0.99
..
0.98
0.01
0.006
..
0.990
0.002
0.015
..
2.475
0.005
0.03
..
5.94
0.01
0.06
..
9.90
0.02
0.10
..
15.80
0.05
0.2
..
39.6
0.1
0.6
..
99.0
0.2
1.5
..
247.5
0.5
2
..
396
1
3
..
594
1
in bar
in bar
-0.95
..
0.98
0.01
0.024
..
0.990
0.002
0.060
..
2.475
0.005
0.14
..
5.94
0.01
0.24
..
9.90
0.02
0.40
..
15.80
0.05
0.9
..
39.6
0.1
2.4
..
99.0
0.2
6.0
..
247.5
0.5
9
..
396
1
14
..
594
1
E
37