ENS 3000
12.2 OTHER MESSAGES
Other messages that cannot be acknowledged by pressing any key may also appear on
the display.
Possible message, if the ENS has not yet been used:
Flashing display of all centre LEDs.
The ENS detects an undefined condition, i.e. the level of the fluid is outside the
active zone. Therefore the level is either too low or too high.
If level is too low: top up the fluid until a valid measurement is detected.
Action:
If level is too high: drain the fluid until a valid measurement is detected.
Possible message, if ENS has already been in use:
0.0 resp. flashing offset A flashing zero value in the display
The ENS detected a change in fluid level which is below the active zone. The
last reliable fluid level measured is less than the average value of the unit's
effective range.
A flashing non-zero value in the display
xx.x
The ENS detected a change in the fluid level which is higher than the active
zone. The last reliable fluid level measured is greater than the average value
of the unit's effective range. Possible values for x.xx: 17.0; 29.0; 39.0, 59.0
(without offset values)
Flashing left and right centre LED.
The ENS has detected a fault and the distance between the imperfection and
the measurement signal is so small that no clear measurement signal can be
identified. The last valid status of the switching output and the analogue output
remain maintained.
Status 19.09.2018
HYDAC ELECTRONIC GMBH
Page25
Part No. 669849