ENS 3000
Other data
Max. tank pressure
Supply voltage
when applied according to UL specifications
Current consumption
Residual ripple of supply voltage
Fluids
Parts in contact with fluid
Display
Weight
Note:
Reverse polarity protection of the supply voltage, excess voltage, override and short circuit
protection are provided.
FS (full scale) = regarding the complete measuring range
*
specifies (at constant level)
** environmental conditions according to 1.4.2 UL 61010-1; C22.2 No. 61010-1
*** further fluids on request
Status 19.09.2018
0.5 bar (short-term 3 bar t < 1 min)
9 .. 35 V DC without analogue output
18 .. 35 V DC with analogue output
- limited energy –
according to
9.3 UL 61010; Class 2;
UL 1310 / 1585; LPS UL 60950
max. 2.470 A
max. 90 mA
≤ 5 %
Hydraulic oils (mineral based), synth. oils,
fluids containing water ***
Ceramic
4-digit, LED, 7 segment, red,
height of digits 7 mm
180 .. 300 g, according to probe length
HYDAC ELECTRONIC GMBH
Page28
total
inactive
switching outputs and
2 analogue outputs
Part No. 669849