Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

All manuals and user guides at all-guides.com
Elektronischer
Druckschalter
Electronic
Pressure Switch
Manocontacteur
électronique
EDS 1700

Publicité

loading

Sommaire des Matières pour HYDAC ELECTRONIC EDS 1700

  • Page 1 All manuals and user guides at all-guides.com Elektronischer Druckschalter Electronic Pressure Switch Manocontacteur électronique EDS 1700...
  • Page 2 all-gui des.c...
  • Page 3 All manuals and user guides at all-guides.com...
  • Page 4 All manuals and user guides at all-guides.com Inhalt Funktionen des EDS 1700 1.1. HAFTUNGSAUSSCHLUSS Montage Bedienelemente der Folien tastatur Digitalanzeige Ausgangsverhalten 5.1. RELAISAUSGÄNGE 5.2. ANALOGAUSGANG 5.3. EINSTELLEN DER SCHALTPUNKTE UND RÜCKSCHALTPUNKTE/HYSTERESEN Einstellen eines Schaltpunktes 5.3.1 5.3.2 Einstellen einer Hysterese 5.3.3 Einstellen eines Rückschaltpunktes...
  • Page 5  Schalten der 4 Relaisausgänge entsprechend dem Druck und den eingestellten Schaltpunkten und Hysteresen bzw. Rückschaltpunkten.  Erfassen des maximalen Druckes seit Einschalten des Gerätes.  Menü zur Grundeinstellung (Anpassen des EDS 1700 an die jeweiligen Applikation).  Programmierfreigaben.  Ändern der Einbaulage (Druckanschluss von oben oder unten) 1.1.
  • Page 6 All manuals and user guides at all-guides.com Bedienelemente der Folientastatur Schrauben zum Entfernen des Bedienteils 4-stellige Digitalanzeige Tasten zur Einstellung der Schaltpunkte und Zusatzfunktionen Digitalanzeige Nach Einschalten der Versorgungsspannung zeigt das Gerät kurz "EdS" an und beginnt mit der Anzeige des aktuellen Druckes. Hinweise: ...
  • Page 7 All manuals and user guides at all-guides.com Ausgangsverhalten 5.1. RELAISAUSGÄNGE Der EDS 1700 besitzt 4 Relaisausgänge. Zu jedem Relais kann ein Schaltpunkt und ein Rückschaltpunkt bzw. eine Hysterese eingestellt werden. Das jeweilige Relais zieht an wenn der eingestellte Schaltpunkt erreicht wurde und fällt ab wenn der Rückschaltpunkt unterschritten wurde.
  • Page 8 all-gui des.c...
  • Page 9 All manuals and user guides at all-guides.com 5.3.2 Einstellen einer Hysterese (Nur möglich wenn der Rückschaltmodus auf "Hysterese" gesetzt ist.) Druckanzeige Taste OFF Anzeige Hysterese einstellen betätigen = Wert größer = Wert kleiner 5.3.3 Einstellen eines Rückschaltpunktes (Nur möglich wenn der Rückschaltmodus auf "Rückschaltpunkt" gesetzt ist.) Druckanzeige Taste OFF Anzeige...
  • Page 10 All manuals and user guides at all-guides.com Maximalwert Der Maximalwert ist der höchste Druckwert, der seit Einschalten des Gerätes oder seit dem letzten Rücksetzvorgang aufgetreten ist. 6.1. ANSEHEN DES MAX-WERTES Druckanzeige Tasten ON und Anzeige Maximalwert wird OFF von Schalt- angezeigt punkt 4 gleich- zeitig betätigen...
  • Page 11 All manuals and user guides at all-guides.com Grundeinstellungen Zur Anpassung an die jeweilige Applikation kann das Verhalten des EDS 1700 über mehrere Grundeinstellungen verändert werden. Diese sind zu einem Menü zusammengefasst. 7.1. ÄNDERN DER GRUNDEINSTELLUNGEN Einstellung ändern danach Tasten ON und Anzeige Mit einzelner Taste Menüpunkt...
  • Page 12 Rückschaltpunkt unterschritten sein muss damit ein Schaltvorgang erfolgt. Relais 2..4 wie oben Rückschaltmodus (Switch Mode) R.S.P./ HYST. "R.S.P": Der EDS 1700 arbeitet mit ein- HYST. stellbaren Rückschaltpunkten. "HYST": Der EDS 1700 arbeitet mit ein- stellbaren Hysteresen. (siehe auch Kapitel 5.1. "Relaisausgänge")
  • Page 13 All manuals and user guides at all-guides.com Einstellung Anzeige Einstell- Vorein- bereich stellung Primäranzeige (Primär) ACT/ ACT. Anzeigewert der permanent in der Anzeige S.P.1.. stehen soll: S.P.4/ "ACT.": aktueller Druck "S.P.1" .. "S.P.4": Schaltpunkt 1 .. 4 "MAX": Maximalwert Anzeigefilter (Display) SLOW/ MED.
  • Page 14 all-gui des.c...
  • Page 15 Einheit angezeigt. Kommastelle (Point) 0 .. (nur bei Einstellung "RANG" = "FREE") 0.000 Anzahl der Nachkommastellen, die der EDS 1700 anzeigt. Unterer Anzeigebereich (Range Low) -995 .. (nur bei Einstellung "RANG" = "FREE") 9995 Untere Anzeigebereichsgrenz Oberer Anzeigebereich (Range High) -995 ..
  • Page 16 All manuals and user guides at all-guides.com Einstellung Anzeige Einstell- Vorein- bereich stellung Analogausgang (Output) MAMP/ VOLT "MAMP": Der Analogausgang liefert VOLT ein 4 .. 20 mA Signal. "VOLT": Der Analogausgang liefert ein 0 .. 10 V Signal. Verstecktes Grundeinstellungsmenü YES/NO (Hide) "YES":...
  • Page 17 All manuals and user guides at all-guides.com 8.2. ÄNDERN DER HARDWARE-PROGRAMMIERFREIGABE  Gerät von der Versorgungsspannung trennen.  Die 4 Schrauben der Gerätefrontplatte entfernen (Bild 1).  Frontplatte vorsichtig abheben und zur Seite legen.  Schiebeschalter auf der unteren Platine in die gewünschte Position schalten (Bild 2): "OFF": Programmierung gesperrt ...
  • Page 18 All manuals and user guides at all-guides.com 10. Fehlermeldungen Wird ein Fehler erkannt, so erscheint eine entsprechende Fehlermeldung, die mit einem beliebigen Tastendruck quittiert werden muss. Mögliche Fehlermeldungen sind: ER.01 Die Schaltpunkte und Hysteresen/Rückschaltpunkte liegen nicht im erlaubten Einstellbereich. Beispiel: Ein Schaltpunkt wird auf 180 bar eingestellt, die Hysterese auf 200 bar.
  • Page 19 Anzugsdrehmoment 20 Nm Medienberührende Teile Anschlussstück: Edelstahl Ausgangsgrößen: Genauigkeit: EDS 1700-P: ≤ ±0,5 % FS max. (Anzeige, Analogausgang) EDS 1700-N: ≤ ±1,0 % FS max. Reproduzierbarkeit: EDS 1700-P: ≤ ±0,25 % FS max. EDS 1700-N: ≤ ±0,5 % FS max.
  • Page 20 all-gui des.c...
  • Page 21 All manuals and user guides at all-guides.com Sonstige Größen: Versorgungsspannung 22 .. 32 V DC Stromaufnahme ca. 200 mA Restwelligkeit ≤ 10 % Anzeige 4-stellig, LED, 7-Segment, rot, Zeichenhöhe 13 mm Elektrischer Anschluss Steck-Klemmenblock, 14-polig Gehäusewerkstoff Aluminium eloxiert Gewicht ca. 800 g Anmerkung: FS (Full Scale) = bezogen auf den vollen Messbereich Verpolungsschutz der Versorgungsspannung, Überspannungs-, Übersteuerungsschutz, Lastkurzschlussfestigkeit sind vorhanden.
  • Page 22 All manuals and user guides at all-guides.com 13. Bestellangaben EDS 1 7 9 X - X - XXX - 000 Serien-Nr. Anschlussart, mechanisch = Einschraubloch DIN 3852-G 1/4 Anzeige = 4-stellig bar = 4-stellig psi Genauigkeit = 0,5 % = 1 % Druckbereich in bar 016, 040, 100, 250, 400, 600 Modifikationsnummer...
  • Page 23 All manuals and user guides at all-guides.com 15. Geräteabmessungen Kabelverschraubung PG 11 Einschraubloch G 1/4 Senkung DIN 74-Km5...
  • Page 24 All manuals and user guides at all-guides.com...
  • Page 25 All manuals and user guides at all-guides.com Contents Functions of EDS 1700 1.1. EXCLUSION OF LIABILITY Mounting Operating keys on the membrane keypad Digital display Output function 5.1. RELAY OUTPUTS 5.2. ANALOGUE OUTPUT 5.3. SETTING THE SWITCHING POINTS AND SWITCH-BACK POINTS/HYSTERESES Setting a switching point 5.3.1...
  • Page 26 all-gui des.c...
  • Page 27 German is legally valid Mounting The EDS 1700 is mounted via the 4 mounting holes in the rear panel of the housing. The pressure connection must be via Minimess line for mechanical decoupling. In critical applications (e.g. strong vibrations or knocks), the EDS 1700 must be mounted on rubber buffers (DIN vibration mounts).
  • Page 28 All manuals and user guides at all-guides.com Operating keys on the membrane keypad undo screws to remove operating panel 4-digit digital display keys for setting the switching points and additional functions Digital display After switching on the supply voltage, the unit briefly displays "EdS" and then displays the current pressure.
  • Page 29 Output function 5.1. RELAY OUTPUTS The EDS 1700 has 4 relay outputs. One switching point and one switch-back point and/or one hysteresis can be set for each relay. The appropriate relay pulls in when the pre-set switching point is reached and drops back when the pressure falls below the switch-back point.
  • Page 30 All manuals and user guides at all-guides.com 5.3.2 Setting a hysteresis (Only possible if the switch-back mode is set to "hysteresis".) pressure display press OFF display set hysteresis = larger value = smaller value 5.3.3 Setting a switch-back point (Only possible if the switch-back mode is set to "switch-back point".) pressure display press OFF...
  • Page 31 All manuals and user guides at all-guides.com Maximum value The maximum value is the highest pressure value that has occurred since the unit was switched on or since the last re-set. 6.1. VIEWING THE MAX VALUE pressure display press ON and display maximum value OFF keys of...
  • Page 32 all-gui des.c...
  • Page 33 To close the basic setting menu: Call up the menu point END, set to YES, the EDS 1700 returns to the normal display mode after 2s. Press ON and OFF keys of switching point 1 simultaneously, END is displayed, the EDS 1700 returns to normal display mode after 2s.
  • Page 34 Relays 2..4 as above Switch-back mode (Switch Mode) R.S.P./ HYST. "R.S.P": The EDS 1700 operates with HYST. adjustable switch-back points. "HYST": The EDS 1700 operates with adjustable hystereses. (see also point 5.1 "Relay outputs")
  • Page 35 All manuals and user guides at all-guides.com Setting Display Setting Pre- range setting Primary display (Primary) ACT/ ACT. Display value which should remain S.P.1.. remain permanently in the display: S.P.4/ "ACT.": current pressure "S.P.1" .. "S.P.4": switching point 1..4 "MAX": maximum value Display filter (Display) SLOW/...
  • Page 36 7 seconds. Decimal places (Point) 0 .. (only when set to "RANG"="FREE") 0.000 Number of decimal places which the EDS 1700 displays. Lower display range (Range Low) -995 .. (only when set to "RANG"="FREE") 9995 Lower display range limit Upper display range (Range High) -995 ..
  • Page 37 All manuals and user guides at all-guides.com Setting Display Setting Pre- range setting Analogue output (Output) MAMP/ VOLT "MAMP": The analogue output supplies VOLT a 4..20 mA signal. "VOLT": The analogue output supplies a 0..10 V signal Hidden basic settings menu YES/NO (Hide) "YES":...
  • Page 38 all-gui des.c...
  • Page 39 All manuals and user guides at all-guides.com 8.2. ALTERING THE HARDWARE PROGRAMMING ENABLE  Disconnect the unit from the supply voltage.  Remove the 4 screws from the unit front panel (Illustration 1).  Lift front panel off carefully and put to one side. ...
  • Page 40 All manuals and user guides at all-guides.com 10. Error messages If an error is detected, then a corresponding error message appears which must be acknowledged by pressing any key. Possible error messages are as follows: ER.01 The switching points and hystereses/switch-back points are not within the permissible setting range.
  • Page 41 20 Nm Parts in contact with medium Mech. connection: Stainless steel Output data: Accuracy to DIN 16086, EDS 1700-P: ≤ ±0.5 % FS max. max. setting EDS 1700-N: ≤ ±1.0 % FS max. (Display, Analogue output) Repeatability: EDS 1700-P: ≤ ±0.25 % FS max.
  • Page 42 All manuals and user guides at all-guides.com Other data: Supply voltage 22 .. 32 V DC Current consumption approx. 200 mA Residual ripple ≤ 10 % Display 4-digit 7 segment LED display, red, height of digits: 13 mm Electrical connection 14-pole, terminal block Housing material aluminium, anodised...
  • Page 43 All manuals and user guides at all-guides.com 13. Model code EDS 1 7 9 X - X - XXX - 000 Series no. Type of connection, mechanical = G 1/4" female thread to DIN 3852, Form X Display = 4 digit bar = 4 digit psi Accuracy = 0.5 %...
  • Page 44 all-gui des.c...
  • Page 45 All manuals and user guides at all-guides.com 15. Dimensions cable gland PG 11 threaded port G 1/4 countersunk to DIN 74-Km5...
  • Page 46 All manuals and user guides at all-guides.com...
  • Page 47 APERÇU DES REGLAGES DE BASE Autorisation de programmation 8.1. MODIFICATION DES DROITS DE PROGRAMMATION 8.2. MODIFICATION MATERIELLE DE LA PROGRAMMATION Possibilités de montage de l'EDS 1700 Messages d'erreur Données techniques Raccordement Données de commande Accessoires livrés 14.1. MATERIEL LIVRE EN STANDARD 14.2.
  • Page 48  Acquisition de la pression maximale depuis la mise sous tension de l’appareil .  Menu pour établir les réglages de base (adapter l’EDS 1700 pour la fonction désirée)  Verrouillage de programmation possible  Modification de la position de montage...
  • Page 49 Touches pour réglage des points de commutation et fonctions annexes Afficheur numérique Après l'avoir mis sous tension, l'EDS 1700 indique brièvement "EDS"puis donne la valeur de pression actuelle. Remarque:  L'affichage peut être modifié dans le réglage de base de façon à ce qu'au démarrage la valeur de point de déclenchement ou de la valeur maximale...
  • Page 50 all-gui des.c...
  • Page 51 All manuals and user guides at all-guides.com Comportement en sortie 5.1. SORTIES SUR RELAIS L'EDS1700 possède 4 relais. Pour chaque relais, il est possible de régler un déclenchement et un réenclenchement ou hystérésis. Le relais concerné bascule quand la valeur réglée est atteinte, et revient dans l'état initial quand la pression redescend en dessous de la valeur préréglée.
  • Page 52 All manuals and user guides at all-guides.com 5.3.2 Réglage des hystérésis (Pour mode de réenclenchement réglé sur "hystérésis" uniquement) Valeur Press. Appuyer Indication Régler la valeur du seuil sur ON = augmenter = diminuer 5.3.3 Réglage du point de réenclenchement (Pour mode de réenclenchement réglé...
  • Page 53 All manuals and user guides at all-guides.com Valeur maximale Cette valeur est la valeur maximale de pression atteinte depuis que l'appareil a été mis sous tension ou depuis le dernier RESET. 6.1. VISUALISATION DE LA VALEUR MAXIMALE Indication Pr. Appuyer Indication Affichage de la valeur MAX simultanément...
  • Page 54 Sortie du menu "réglage de base": Sélectionner "END" puis "YES": l'EDS1700 retourne alors dans le mode affichage normal. Appuyer sur les touches "ON" et "OFF" du seuil 1, "END" s'affiche: l'EDS 1700 retourne alors dans le mode d'affichage standard. Remarques: ...
  • Page 55 Relais 2..4 réglés de manière identique Mode commutation (Switch Mode) R.S.P./ HYST. "R.S.P": L’EDS 1700 travaille avec HYST. point de déclenchement. "HYST": L’EDS 1700 travaille avec une hystérésis. (voir également chap. 5.1. "Sorties sur relais")
  • Page 56 all-gui des.c...
  • Page 57 All manuals and user guides at all-guides.com Réglages Indication Plage de- Préré- réglage glage Indication primaire ACT/ ACT. La valeur d’affichage peut être: S.P.1.. "ACT.": Pression actuelle S.P.4/ "S.P.1" .. "S.P.4": Point de commutation 1 à 4 "MAX": Valeur maximale Filtre d’affichage (Display) SLOW/ MED.
  • Page 58 All manuals and user guides at all-guides.com Réglages Indication Plage de- Préré- réglage glage Visualisation de l’unité (Unit) YES/NO (uniquement avec les choix "RANG" ="BAR" ou ="PSI") En sélectionnant "YES" l’unité sera affichée toutes les 7 secondes. Position de la virgule (Point) 0 ..
  • Page 59 All manuals and user guides at all-guides.com Réglages Indication Plage de- Préré- réglage glage Sortie analogique (Output) MAMP/ VOLT "MAMP": Le signal en sortie est du VOLT type 4..20 mA. "VOLT": Le signal en sortie est du type 0..10V. Masquage du menu de base YES/NO (Hide) "YES":...
  • Page 60 Fig. 1 Fig. 2 Possibilites de montage de l'EDS 1700  Couper l'alimentation de l'appareil.  Dévisser les 4 vis frontales (fig. 1).  Soulever la plaque avant et la tourner de 180°.  Replacer la plaque avant dans le boîtier et la fixer au moyen des 4 vis.
  • Page 61 All manuals and user guides at all-guides.com 10. Messages d'erreur En situation d'erreur, une information correspondante s'affiche. Celle-ci peut être validée en appuyant sur une touche. Différentes erreurs: ER.01 Les valeurs des points d'enclenchement / déclenchement (ou hystérésis) ne sont pas comprises dans la plage de mesure. Exemple: Un point de commutation est réglé...
  • Page 62 all-gui des.c...
  • Page 63 20 Nm Matér. en contact avec le fluide Raccord: Acier inox Sortie: Précision selon DIN 16086, EDS 1700-P: ≤ ±0,5 % type PE Réglage du seuil EDS 1700-N: ≤ ±1,0 % PE max. (affichage, sortie analogique) Reproductibilité: EDS 1700-P: ≤ ±0,25 % PE max.
  • Page 64 All manuals and user guides at all-guides.com Autres grandeurs: Tension d’alimentation 22 .. 32 V DC Consommation électrique env. 200 mA Oscillation résiduelle ≤ 10 % de la tension d'alim. Indicateur 4 positions 7 segments à LED, rouge, hauteur 13 mm Raccordement électrique Bornier à...
  • Page 65 All manuals and user guides at all-guides.com 13. Code de commande EDS 1 7 9 X - X - XXX - 000 N° de série interne Raccordement mécanique = G1/4 taraudé selon DIN 3852, forme X Indicateur = 4 positions bar = 4 positions psi Précision = 0,5 %...
  • Page 66 All manuals and user guides at all-guides.com 15. Dimensions de l'appareil Raccordement par presse-étoupe PG 11 Raccordement G 1/4 Lamage DIN 74-Km5...
  • Page 67 Fax: +1 905 / 714 46 64 Alam Sutera - Serpong E-mail: sales@hydac.ca Tangerang Selatan 15325 Internet: www.hydac.ca Tel.: +62 21 2921 1671 / 2921 1672 Fax: +62 21 2921 1653 HYDAC Electronic GMBH Hauptstraße 27 E-mail: info@hydac.co.id 66128 Saarbrücken Internet: www.hydac.co.id Phone: +49 6897 509-01...