Step 6 Mix a solution of cleaner and lukewarm water.
Depending upon the amount of mineral buildup, a larger
quantity of solution may be required. Use the ratio in the
table below to mix enough solution to thoroughly clean
all parts.
Solution Type
Water
Cleaner
1 gal. (4 l)
Step 7 Use 1/2 of the cleaner/water mixture to clean all
components. The cleaner solution will foam when it
contacts lime scale and mineral deposits; once the
foaming stops use a soft-bristle nylon brush, sponge or
cloth (NOT a wire brush) to carefully clean the parts. All
parts except the ice thickness probe can be soaked
when heavily scaled. Rinse all components with clean
water.
Step 8 While components are soaking, use 1/2 of the
cleaner/water solution to clean all foodzone surfaces of
the ice machine and bin (or dispenser). Use a nylon
brush or cloth to thoroughly clean the following ice
machine areas:
Side walls
Base (area above water trough)
Evaporator plastic parts - including top, bottom, and
sides
Bin or dispenser
Rinse all areas thoroughly with clean water.

SANITIZING PROCEDURE

Step 9 Mix a solution of sanitizer and lukewarm water.
Solution Type
Water
Sanitizer
3 gal. (12 l)
Step 10 Use 1/2 of the sanitizer/water solution to
sanitize all removed components. Use a spray bottle to
liberally apply the solution to all surfaces of the removed
parts or soak the removed parts in the sanitizer/water
solution. Do not rinse parts after sanitizing.
Part Number 000007924 5/14
Mixed With
16 oz (500 ml) cleaner
Mixed With
2 oz (60 ml) sanitizer
Step 11 Use 1/2 of the sanitizer/water solution to
sanitize all foodzone surfaces of the ice machine and bin
(or dispenser). Use a spray bottle to liberally apply the
solution. When sanitizing, pay particular attention to the
following areas:
Side walls
Base (area above water trough)
Evaporator plastic parts - including top, bottom and
sides
Bin or dispenser
Do not rinse the sanitized areas.
Step 12 Replace all removed components.
Step 13 Wait 20 minutes.
Step 14 Reapply power to the ice machine and perform
the following key strokes.
Press Clean button
Press right arrow button, select clean yes button
Press checkmark button
Press right arrow button, select auto start yes button
Press checkmark button
Step 15 Wait until the water trough refills and the
display indicates add solution (approximately 1 minute).
Add the proper amount of Manitowoc Ice Machine
Sanitizer to the water trough
Model
I0680C/I0870C/I0970C/
I1070C/I1176C
IB0690C/IB0890C
IB1090C
I1470C/I1870C/I2170C
Step 16 Close and secure the front door. The ice
machine will automatically start ice making after the
sanitize cycle is complete (approximately 24 minutes).
Maintenance
Amount of Sanitizer
3 ounces (90 ml)
3 ounces (90 ml)
3.5 ounces (104 ml)
12 ounces (355 ml)