Section 2

Operational Checks

GENERAL

Manitowoc ice machines are factory-operated and
adjusted before shipment. Normally, new installations do
not require any adjustment.
To ensure proper operation, always follow the
Operational Checks:
when starting the ice machine for the first time
after a prolonged out of service period
after cleaning and sanitizing
NOTE: Routine adjustments and maintenance
procedures are not covered by the warranty.
REMOVE ICE THICKNESS PROBE SHIPPING
BRACKETS
REMOVE & DISCARD
Part Number 000007924 5/14

ICE THICKNESS CHECK

After a harvest cycle, inspect the ice cubes in the ice
storage bin. The ice thickness probe is factory-set to
maintain the ice bridge thickness at 1/8" (3 mm).
NOTE: Make sure the water curtain is in place when
performing this check. It prevents water from splashing
out of the water trough.
1. Inspect the bridge connecting the cubes. It should
be about 1/8" (3 mm) thick.
2. If adjustment is necessary, turn the ice thickness
probe adjustment screw clockwise to increase
bridge thickness, counterclockwise to decrease
bridge thickness. Set at 9/32" (7mm) gap between
ice thickness probe and evaporator as starting point,
then adjust to achieve a 1/8" bridge thickness.
NOTE: Turning the adjustment 1/3 of a turn will change
the ice thickness about 1/16" (1.5 mm).
ADJUSTING SCREW
1/8" ICE BRIDGE THICKNESS
PLACE DRILL BIT HERE
BETWEEN PROBE AND
EVAPORATOR TO SET
INITIAL GAP
Ice Thickness Check
3. Make sure the ice thickness probe wire and the
bracket do not restrict movement of the probe.
Installation
25