! Caution
Clean and sanitize bin and cart(s) interiors prior to
use and on regular schedule as needed. Use only
Manitowoc approved Ice Machine Cleaner (94-
0546-3 or 000000084) and Sanitizer (94-0565-3) for
this application. Do NOT use chlorine-based
cleaners, which can cause staining and pitting of
stainless steel components. Do not run Totes
through a dishwasher. Turn off ice machine(s) and
remove ice from bin before beginning.
!
Wear rubber gloves and safety goggles (and/or face
shield) when handling Ice Machine Cleaner or
Sanitizer.
Cleaning and Sanitizing Interior Bin
Interior of bin must be cleaned and sanitized prior to use
and should be cleaned on a routine basis during use.
The ice storage bin is equipped with polyethylene liner
walls which must be cleaned and sanitized every six
months with Manitowoc Ice Machine Cleaner and
Sanitizer.
1. Remove upper inspection windows by sliding
windows to one side. Grasp the end of the front
window and pull toward you as the window is slid to
the opposite side. Repeat for rear window.
2. Mix a solution of cleaner and warm water.
Depending upon the amount of mineral buildup, a
larger quantity of solution may be required. Use the
ratio in the table below to mix enough solution to
thoroughly clean all parts.
Solution Type
Cleaner
1 gal. (4 L)
Part Number 000006529 10/09
Maintenance
Warning
REAR WINDOW
FRONT WINDOW
Water
Mixed With
16 oz. (500 ml)
cleaner
Section 4
3. Wash bin walls, hopper, access door plate and
partition (if any), and rinse all areas thoroughly with
clean water.
Do not rinse after sanitizing.
4. Mix a solution of sanitizer and warm water.
Solution Type
Sanitizer
5. Sanitize bin walls, hopper and access door plate.
Use a spray bottle to liberally apply the solution. Do
not rinse the sanitized areas.
6. Clean and sanitize the ice delivery carts.
A. Wash cart liner with an approved cleaner.
B. Rinse all areas thoroughly with clean water.
C. Sanitize the cart - Use a spray bottle to liberally
apply the solution. Do not rinse the sanitized
areas.
7. Remove the following bin components for cleaning
and sanitizing.
•
Shutter Door
•
Drain Tray
•
Bin Drain Lines
8. Use cleaning solution to clean the removed
components, rinse with clean water and sanitize (do
not rinse after sanitizing).
9. Clean, rinse and sanitize the shutter door rails.
10. Reassemble all removed components.
Important
Water
Mixed With
3 gal. (11 L)
2 oz. (60 ml)
sanitizer
9