Interior Cleaning and Sanitizing
GENERAL
Clean and sanitize the ice machine every six months for
efficient operation. If the ice machine requires more
frequent cleaning and sanitizing, consult a qualified
service company to test the water quality and
recommend appropriate water treatment.
The ice machine must be taken apart for cleaning and
sanitizing.
! Caution
Use only Manitowoc approved Ice Machine Cleaner
(part number 94-0546-3) and Sanitizer (part
number 94-0565-3). It is a violation of Federal law
to use these solutions in a manner inconsistent with
their labeling. Read and understand all labels
printed on bottles before use.
CLEANING AND SANITIZING PROCEDURE
! Caution
Do not mix Ice Machine Cleaner and Sanitizer
solutions together. It is a violation of Federal law to
use these solutions in a manner inconsistent with
their labeling.
!
Wear rubber gloves and safety goggles (and/or face
shield) when handling Ice Machine Cleaner or
Sanitizer.
Ice machine cleaner is used to remove lime scale and
mineral deposits. Ice machine sanitizer disinfects and
removes algae and slime.
Step 1 Set the toggle switch to the OFF position after
ice falls from the evaporator at the end of a Harvest
cycle. Or, set the switch to the OFF position and allow
the ice to melt off the evaporator.
! Caution
Never use anything to force ice from the evaporator.
Damage may result.
Step 2 Remove all ice from the bin.
10
Maintenance
Warning
Section 4
Step 3 To start a cleaning cycle, move the toggle switch
to the WASH position.
Step 4 Wait until water flows over the evaporator
(about three minutes) then add the proper amount of
Manitowoc Ice Machine Cleaner to the water trough.
Model
QM30
Step 5 Wait until the clean cycle is complete
(approximately 45 minutes) then place the toggle switch
in the OFF position, disconnect power and water
supplies to the ice machine.
Disconnect electric power to the ice machine at the
electric switch box before proceeding.
Step 6 Remove parts for cleaning.
A. Remove the Overflow Tube
•
To remove the tube, lift it up while using a slight back
and forth motion to loosen it from the drain hole.
When installing the tube, be sure it is completely
inserted into the drain hole to prevent water leakage
during normal operation.
DRAIN
HOLE
Removing the Overflow Tube
Amount of Cleaner
45 ml
!
Warning
OVERFLOW
TUBE
Part Number 00000xxxx 05/10