Installation

Refrigeration System Installation

Remote Single
QuietQube
®
Ice Machine
Condenser
I0680C
ICVD0695
IB690C
I0870C
ICVD0895
IB890C
I0970C
ICVD0996
I1070C
ICVD1095
I1176C
ICVD1195
IB1090C
I1470C
ICVD1495
I1870C
ICVD1895
I2170C
ICVD2095
Suction
*Line Set
Line
5/8 inch
RC 26/36/56
(16 mm)
3/4 inch
RC 25/35/55
(19 mm)
3/4 inch
RC 28/38/58
(19 mm)
Important
Manitowoc remote systems are only approved and
warranted as a complete new package. Warranty
on the refrigeration system will be void if a new ice
machine head section is connected to pre-existing
(used) tubing or condensing units or vice versa.
18
Circuit
Line Set*
RC-26
RC-36
RC-56
RC-25
RC-35
RC-55
RC-28
RC-38
RC-58
Minimum
Liquid
Insulation
Line
Thickness
1/2" (13mm)
3/8 inch
Suction Line
(10 mm)
1/4" (7mm) Liquid
Line
1/2" (13mm)
1/2 inch
Suction Line
(13 mm)
1/4" (7mm) Liquid
Line
1/2" (13mm)
5/8 inch
Suction Line
(16 mm)
1/4" (7mm) Liquid
Line
! Caution
The refrigeration system warranty will not apply if
the Manitowoc Ice Machine and Manitowoc ICVD
Condensing Unit are not installed according to
specifications. This warranty also will not apply if
the refrigeration system is modified with a
condenser, heat reclaim device, or other parts or
assemblies not manufactured by Manitowoc.
Ice Machine Refrigerant Amounts
ICE MACHINE HEAD SECTION
Each ice machine head section ships from the factory
with a R-404A refrigerant charge appropriate for the
entire system operation. The serial tag on the ice
machine indicates the refrigerant charge.
The refrigerant charge is sufficient to operate the ice
machine at all ambients with lineset lengths up to 100
feet (30 m).
!
Potential Personal Injury Situation
The ice machine head section contains the
refrigerant charge. Installation and brazing of the
line sets must be performed by a properly trained
and EPA certified refrigeration technician aware of
the dangers of dealing with refrigerant charged
equipment.
!
Installation of a QuietQube
require the use of special equipment for placement.
Trained and qualified personnel are required for
proper rigging and lifting. Holes are provided on the
corners of the condensing unit to allow the use of
lifting shackles.
Section 2
Warning
Warning
Condensing Unit may
®
Part Number 000007924 5/14