A. Remove splash shield
Grasp the top center of splash shields.
Lift up and then out.
B. Remove ice thickness probe
Compress the hinge pin on the top of the ice
thickness probe.
Pivot the ice thickness probe to disengage one pin
then the other. The ice thickness probe can be
cleaned at this point without complete removal. If
complete removal is desired, disconnect the ice
thickness control wiring from the control board.
C. Remove the water trough
Depress tabs on right and left side of the water
trough.
Allow front of water trough to drop as you pull forward
to disengage the rear pins.
B
A
C
Part Number 000007924 5/14
D. Remove the water level probe
Pull the water level probe straight down to
disengage.
Lower the water level probe until the wiring connector
is visible.
Disconnect the wire lead from the water level probe.
Remove the water level probe from the ice machine.
E. Remove the water distribution tube
NOTE: Distribution tube thumbscrews are retained to
prevent loss. Loosen thumbscrews but do not pull
thumbscrews out of distribution tube.
Loosen the two outer screws (do not remove screws
completely they are retained to prevent loss) and pull
forward on the distribution tube to release from slip
joint.
Disassemble distribution tube by loosening the two (2)
middle thumbscrews and dividing the distribution tube
into two pieces.
E
D
Maintenance