Tableau 1-9
Tableau d'adaptation pour module puissance 6SN112V–1AA00–0FA1 100/200 A
Servomoteur
C [Nm]
[Nm]
1FT
1FT
C
o
4101–VSK71
20,0
4101–VSN71
20,0
4102–VSG71
33,0
4102–VSK71
33,0
4104–VSG71
45,0
4104–VSK71
45,0
4106–VSG71
59,0
5066–VAK71
6,5
5072–VAG71
10,0
5072–VAK71
10,0
5073–VAK71
7,0
5074–VAF71
14,0
5074–VAG71
14,0
5074–VAK71
14,0
5074–VSG71
16,0
5074–VSK71
16,0
5076–VAC71
18,0
5076–VAF71
18,0
5076–VAG71
18,0
5076–VAK71
18,0
5076–VSG71
20,5
5076–VSK71
20,5
5100–VAF71
10,0
5100–VAG71
10,0
5100–VAK71
10,0
5101–VAC71
15,0
5101–VAF71
15,0
5101–VAG71
15,0
5101–VAK71
15,0
5102–VAA71
27,0
5102–VAC71
27,0
5102–VAF71
27,0
5102–VAG71
27,0
5102–VSF71
34,0
5102–VSG71
34,0
5103–VAC71
19,0
5103–VAF71
19,0
5103–VAG71
19,0
5104–VAA71
37,0
5104–VAC71
37,0
5104–VAF71
37,0
5104–VSF71
48,0
5106–VAA71
45,0
5106–VAC71
45,0
5106–VAF71
45,0
5106–VSF71
57,0
1) La valeur indiquée est le courant maximal admissible de l'ensemble partie puissance-moteur. Suivant le système mé-
canique entraîné, une réduction de la valeur indiquée peut s'avérer nécessaire.
AV/1-14
I [A]
[A]
[tr/min]
[tr/min]
I
n
n
o
nom
33,0
6000
39,0
8000
35,0
4000
47,0
6000
46,0
4000
60,0
6000
56,0
4000
11,6
6000
12,0
4000
17,5
6000
12,5
6000
13,0
3000
16,5
4000
25,0
6000
19,0
4000
28,0
6000
11,5
2000
16,5
3000
21,5
4000
32,0
6000
24,5
4000
36,0
6000
9,2
3000
12,5
4000
18,0
6000
9,4
2000
14,5
3000
17,5
4000
26,5
6000
9,9
1200
16,5
2000
25,0
3000
31,5
4000
31,5
3000
39,5
4000
12,0
2000
17,5
3000
23,0
4000
14,0
1200
22,5
2000
34,0
3000
44,0
3000
17,0
1200
26,8
2000
42,5
3000
54,0
3000
Définition:
o = contact en position de base OFF
x = contact en position ON
SIMODRIVE 611 analogique Manuel de mise en service (IAA) – Edition 10.00
1)
Limite de courant
Interrupteur
[A]
[A]
I
I
max
2
3
4
5
o
x
o
o
136,0
x
o
o
o
170,0
x
o
o
o
170,0
o
o
o
o
200,0
o
o
o
o
200,0
o
o
o
o
200,0
o
o
o
o
200,0
o
x
o
x
60,0
o
x
o
x
60,0
o
x
x
o
82,0
o
x
o
x
60,0
o
x
o
x
60,0
o
x
x
o
82,0
o
o
x
o
100,0
o
x
x
o
82,0
o
o
x
o
100,0
o
o
x
x
52,0
x
x
x
o
78,0
o
o
x
o
100,0
o
x
o
o
136,0
o
o
x
o
100,0
o
x
o
o
136,0
x
x
x
x
46,0
o
x
o
x
60,0
x
o
x
o
92,0
x
x
x
x
46,0
o
x
o
x
60,0
x
o
x
o
92,0
o
x
o
o
136,0
x
x
x
x
46,0
x
x
x
o
78,0
o
o
x
o
100,0
o
x
o
o
136,0
x
x
o
o
122,0
o
x
o
o
136,0
o
x
o
x
60,0
x
o
x
o
92,0
x
x
o
o
122,0
o
x
o
x
60,0
o
o
x
o
100,0
o
x
o
o
136,0
o
x
o
o
136,0
x
x
x
o
78,0
x
x
o
o
122,0
o
o
o
o
200,0
o
o
o
o
200,0
Siemens AG 2000 All Rights reserved
10.00
10.00
07.94
Gain régul. de courant
Interrupteur
Kp(I)
Kp(I)
6
7
8
9
x
x
o
o
2,5
x
x
o
o
2,0
o
o
x
x
9,5
o
x
x
o
5,5
x
o
o
x
6,5
x
x
o
o
2,5
o
x
x
o
5,5
x
o
x
o
4,5
x
x
o
x
8,0
o
x
x
o
5,5
o
o
x
o
4,0
x
x
o
x
8,0
x
o
o
x
6,5
x
x
o
o
2,5
o
o
o
x
6,0
x
x
o
o
2,5
x
x
x
x
11,5
x
x
o
x
8,0
o
x
x
o
5,5
x
x
o
o
2,5
x
o
x
o
4,5
x
x
o
o
2,5
x
x
o
x
8,0
o
o
o
x
6,0
x
o
x
o
4,5
o
o
x
x
9,5
o
o
o
x
6,0
o
o
o
x
6,0
o
o
x
o
4,0
x
x
x
x
11,5
o
o
x
x
9,5
x
o
x
o
4,5
x
o
x
o
4,5
o
x
x
o
5,5
o
o
x
o
4,0
o
o
x
x
9,5
x
o
o
x
6,5
o
x
x
o
5,5
x
x
x
x
11,5
x
x
o
x
8,0
o
x
x
o
5,5
x
o
x
o
4,5
x
x
x
x
11,5
x
x
o
x
8,0
o
x
x
o
5,5
x
o
x
o
4,5