O11 - Power Locks - 1x5P
O14 - Power Locks - 2x5P
Table 9 - Wire marking
Socket
L1
L2
L3
N
X2
2L1
2L2
2L3
2N
X3
3L1
3L2
3L3
3N
X4
4L1
4L2
4L3
4N
X5
5L1
5L2
5L3
5N
X6
6L1
6L2
6L3
6N
X7
7L1
7L2
7L3
7N
X8
8L1
8L2
8L3
8N
X9
9L1
9L2
9L3
9N
X10
10L1
10L2
10L3
10N
X11
11L1
11L2
11L3
11N
Table 10 - 1PH socket connection
Socket slot
Socket 1
Phase
Socket 2
Socket slot 1
X2
L1
X3
Socket slot 2
X4
L3
X5
Socket slot 3
X6
L2
X7
Socket slot 4
X8
L1
X9
Socket slot 5
X10
L3
X11
Configuration set 1
Socket type
Socket slot 1
2x16 1PH or 2x16 3PH or 2x32 3PH
Socket slot 2
2x16 1PH or 2x16 3PH or 2x32 3PH
Socket slot 3
2x16 1PH or 2x16 3PH or 2x32 3PH
Socket slot 4
2x16 1PH or 2x16 3PH or 2x32 3PH
Socket slot 5
2x16 1PH or 2x16 3PH or 2x32 3PH
O12 - Sockets
L3
L2
L1
N
PE
O2 - Dual
frequency
C2
U >
U >
C1
L3
L3
425
L1 L2
L3
PE
N
NOTES
Table 11 - Cross-section/colour
Note 4: This representation of the sockets option is only one example of connection. Several configurations can be made.
Note 5: See Table 9 for wire marking.
Phase
Socket
L1-L2-L3
N
PE
Note 6: See Table 11 for wire cross-section and colour.
L2
16A 1PH
c0
c6
c54
Note 7: Connect 1PH sockets alternating the connection line as shown Table 10.
L1
16A 3PH
c0
c6
c54
Note 8: Two types of circuit breakers migth be selected: magnet-thermal circuit breaker or earth leakage (ELCB) circuit breaker. With 1PH sockets only ELCB can be mounted.
L3
32A 3PH
e0
e6
e54
Note 9: In each socket slot migth be fitted 2 sockets with exception of 63A and 125A sockets, in this case only one socket per slot is allowed. 63A and 125 sockets can only be
L2
63A 3PH
gx0
gx6
gx54
gx54
L1
125A 3PH
hx0
hx6
Configuration set 2
Socket
Circuit braker
Socket type
Label
label
X2, X3
Q2, Q3
2x16 1PH or 2x16 3PH or 2x32 3PH
X4, X5
Q4, Q5
2x16 1PH or 2x16 3PH or 2x32 3PH
X6, X7
Q6, Q7
2x16 1PH or 2x16 3PH or 2x32 3PH
X8, X9
Q8, Q9
2x16 1PH or 2x16 3PH or 2x32 3PH
X10, X11
Q10, Q11
1x63 3PH or 1x125 3PH
C2
C2
U >
C1
C1
T
425
425
L1 L2
L3
PE
N
With 63A and 125A sockets, an earth leakage add-on blockis used when ELCB type is selected.
mounted in slots 3, 4 or 5. There are 4 configuration sets depending on number of the 63A/125A sockets selected: No 63A/125A sockets, 1 unit 63A/125A
socket, 2 units 63A/125A sockets, 1 unit 63A socket and 2 units 63A/125A sockets. Table 12 shows the 4 configurations sets with the corresponding markings of
sockets and circuit breakers.
Table 12 - Socket configuration set
Configuration set 3
Socket
Circuit braker
Socket type
Label
label
X2, X3
Q2, Q3
2x16 1PH or 2x16 3PH or 2x32 3PH
X4, X5
Q4, Q5
2x16 1PH or 2x16 3PH or 2x32 3PH
X6, X7
Q6, Q7
2x16 1PH or 2x16 3PH or 2x32 3PH
X8, X9
Q8, Q9
1x63 3PH or 1x125 3PH
X11
Q11
1x63 3PH or 1x125 3PH
- 171 -
C2
U >
I>>
I>>
I
I
C1
16 A
16 A
30 mA
30 mA
425
N
L1
N
L1
PE
PE
Configuration set 4
Socket
Circuit braker
Socket
Socket type
Label
label
Label
X2, X3
Q2, Q3
2x16 1PH or 2x16 3PH or 2x32 3PH
X2, X3
X4, X5
Q4, Q5
X4, X5
2x16 1PH or 2x16 3PH or 2x32 3PH
X6, X7
Q6, Q7
1x63 3PH
X9
X10
Q10
1x63 3PH or 1x125 3PH
X10
X11
Q11
1x63 3PH or 1x125 3PH
X11
C2
U >
I>>
I
C1
16 A
30 mA
N
L1
PE
Circuit braker
label
Q2, Q3
Q4, Q5
Q9
Q10
Q11