Télécharger Imprimer la page

Bosch DCI 700 Notice Originale page 26

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 55
en | 26 | DCI 700
6.3.2
Substances hazardous to water
 Substances hazardous to water must be disposed of
in accordance with the applicable regulations.
Oil, grease and refuse containing oil or grease
(e.g. filters) are hazardous to water and the envi‐
ronment. Substances hazardous to water must
not be allowed to enter the sewage system.
Test oil as per ISO 4113 is classified under waste
oil collection category 1. Category 1 waste oil
must not contain any foreign substances such as
waste oils of a different category, gasoline or die‐
sel. See the test oil safety data sheet for the cor‐
rect waste code number.
---
7.
Technical data
---
7.1
DCI 700 specifications
Property
Test pressure
Max. rail pressure
Mechanical pressure limit
Pressure control
Return pressure control
High-pressure pump for test pressure
generation
Test oil tank capacity up to min. marking
Test oil tank capacity up to max. marking 50 l
Tightening torque of the high-pressure
connections and threaded plugs
Weight with packaging
Weight without test oil
Rated three-phase voltage
Rated power
Rated current
Number of phases
Frequency
Degree of protection for DCI 700 com‐
plete with monitor, keyboard and mouse
---
7.2
Intended operating conditions
7.2.1
Location
• The area must be enclosed and covered.
• Never expose the DCI 700 to direct sunlight.
• Keep heat sources, e.g. heaters, away from the
DCI 700.
• Degree of contamination 2
---
1 689 989 473 | 2023-09-24
7.2.2
Property
Storage and transportation
Function
Measuring accuracy
---
7.2.3
Property
Maximum permitted relative humidity (at
25 °C and 24 h)
---
7.2.4
Property
Permissible installation height
---
Specification
7.3
30 MPa – 250 MPa
260 MPa
270 MPa
2 pressure control
valves (DRV) and
metering device
(ZME) in CP4
a
50 kPa – 1200 kPa
CP4.2 (CP4-25)
38 l
25 Nm
Approx. 903 kg /
1991 lb
Approx. 613 kg /
a 785 mm
1352 lb
b 700 mm
c 700 mm
200 VAC – 240 VAC
d 1100 mm
11 KW
e 1500 mm
32 A
3 P – protective
conductor
50 Hz / 60 Hz
IP 20
Ambient temperature
Humidity
Air pressure
Dimensions and clearances
b
458921-02_Pal
Specification
-25 °C – 60 °C /
-13 °F – 140 °F
5 °C – 40 °C / 41 °F
– 104 °F
10 °C – 35 °C /
50 °F – 95 °F
Specification
≤90 %
Specification
Up to 2000 m ASL
c
d
e
Robert Bosch GmbH

Publicité

loading