2
3
9. Place a collecting container
of the test oil tank.
10. Open the drain cock of the test oil tank
drain the test oil out of the test oil tank (filling ca‐
pacity = approx. 50 liters) into the collecting con‐
tainer.
– Alternative: Use an external test-oil pump to
pump the test oil out of the test oil tank and into
a collecting container.
11. Dispose of the used test oil. Comply with disposal
 26 "Substances hazardous to wa-
instructions (see
ter").
---
5.2.2.2 Flushing the test oil tank
1. Flush the empty test oil tank with test oil. Collect
the test oil emerging from the drain cock in a col‐
lecting container.
2. Clean the test oil tank with lint-free cloths.
3. Flush again until all dirt residues have been removed
from the test oil tank.
4. Close the drain cock of the test oil tank.
Robert Bosch GmbH
(2)
under the drain cock
(1)
and
1
2
5. Dispose of the used test oil. Comply with disposal
 26 "Substances hazardous to wa-
instructions (see
ter").
---
5.2.2.3 Emptying the heat exchanger
1. Remove the lower cover
DCI 700.
1
2. Place the end of the drain hose
release nipple into a collecting container.
(2)
3. Insert the drain hose
(1)
pling
until it snaps in place.
 The test oil drains from the heat exchanger into
the collecting container.