Télécharger Imprimer la page

Bosch DCI 700 Notice Originale page 18

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 55
en | 18 | DCI 700
2
1
4. Once the heat exchanger is empty at, open the
quick-release coupling and remove the drain hose
from the heat exchanger.
5. Dispose of the used test oil. Comply with disposal
 26 "Substances hazardous to wa-
instructions (see
ter").
6. Attach the cover.
---
5.2.2.4 Filling with test oil
1. Check whether the drain cock of the test oil tank
is closed.
Fill the test oil tank only with fresh and clean test
oil conforming to ISO 4113-CV-AW. For approved
 27 "Test oil conforming to ISO 4113-
test oil, see
CV-AW". Filling capacity = approx. 50 liters.
2. Fill the test oil into the test oil tank through a fine
(1)
up to the "max." marking (3).
filter
1 689 989 473 | 2023-09-24
1
3. Slide the test oil tank cap
4. Tighten the two wing screws
(2)
3
(2)
5. Use the handles
into the test bench.
6. Tighten the two wing screws
2
1
2
(2)
onto the test oil tank.
(1)
and (3).
1
2
(3)
and
to push the test oil tank
(1)
and (4).
Robert Bosch GmbH
3

Publicité

loading