Télécharger Imprimer la page

Bronpi LONDRES Instructions D'installation, D'utilisation Et D'entretien page 34

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 54
STANDBY Function: if parameter Stb =1
If the device is OFF, and the temperature is higher than the value of thermostat TSI
-
The device goes in ON automatically
SAFETY Function: if the parameter SIC = 1
If the probe's temperature is higher than value of thermostat TSI
And the fan is OFF in MANUAL Modality
-
The device goes automatically in the Proportional Modality waiting 10 seconds.
SAFETY FAN Function: if the parameter SAF = 1
If the probe's temperature is higher than value of thermostat TSA
-
The Fan is OFF
ALARM Function:
If probe's temperature is higher than the value of thermostat TAL and the parameter Enb = 1
-
The acoustic signal is activated
-
This signaling can be deactivated for 5 minutes by pushing a button
-
After 5 minutes, if there's again the condition of alarm, it is activated again.
MAIN MENU
FUNCTIONING Modality Selection
-
Press P4 key to see the current modality: it's signaled by the display and the led
-
Pressing again the P4 key, you can select cyclically one of three functioning modality MAN, AUT, PRP signaled on the display and by
the specific led.
-
The setting is automatically memorized after 4 seconds
-
The L5 shows the status of the Fan
SPEED Selection
-
Pressing P2 or P3 keys the setting of the current fan speed is visualized or modified
-
P0= Off (only in Manual); P1 = Minimum Speed; P10= Maximum Speed
-
This function is not available in the PROPORTIONAL Modality
-
In the AUTOMATIC Modality the speeds that can be set are P1 ÷ P10
FAILURE OR ALARM SIGNALS
The controller can signal the failure of the probe blinking message for the failure signal:
-
Lo: indicates a low temperature (temperature under 0°C):Probe Open or Disconnected
-
Hi: indicates a high temperature (temperature over 180°C):Probe in Short Circuit
ATTENTION
-
Avoid join together the probe's cables with power's cables.
-
Provide the system's feeding with a bipolar switch according to the actual rules and with opening distance of the contacts of at least 3
mm for each pole.
-
Installation and the electrical connection of the device have to be made by experienced personal and with appropriate equipping.
-
Before the connection be aware that the electrical feeding is not connected.
SECONDARY MENU
It allows to modify the functioning parameters of the controller.
-
To enter the MENU push together buttons P2 and P3 for about 5 seconds.
-
To scroll the code list use the button P2 or P3
-
To show the parameter's value push the button P4
-
To modify the parameter's value push the buttons P2 or P3
-
To visualize again the code list and memorize push the button P4
-
To exit and memorize wait for about 10 seconds.
The parameters are described in the following table
SECONDARY MENU PARAMETERS
Temperature Fan Activation
Temperature Fan Activation Hysteresis
ALARM Temperature Activation
SAFETY Temperature Activation
SAFETY FAN Temperature Activation
SAFETY Function Enable
SAFETY FAN Function Enable
STANDBY Function Enable
BUZZER Function Enable
Fan Speed P01
Fan Speed P09
Fan Speed P10
Temperature Range of Regulation for Proportional Modality
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
CODE
MIN
SET
30º
iSt
TAL
100º
TSI
80º
TSA
100º
SIC
0 [off]
SAF
0 [off]
Stb
0 [off]
Enb
0 [off]
U01
00
U09
00
U10
00
DEL
20º
33
DEFAULT
MAX
45º
99º
35º
120º
180º
100º
140º
135º
180º
1 [on]
1 [on]
1 [on]
1 [on]
1 [on]
1 [on]
1 [on]
1 [on]
16
100%
70
100%
100
100%
20º
100º
INSERTS

Publicité

loading