In models with fans the start and the control of the ventilation is made by the three-position switch placed on the right bottom side(see
drawing D2.18).
These three-positions have the following functions:
-
0 position: the fans are turned off when there is no combustion inside
the chamber due to the stove is provided with a thermostat that
controls the fan according to the temperature of the insert.
-
1 position: the fans run in a low speed.
-
2 position: the fans run in a high speed.
The models of the Paris series lack thermostat. Therefore, the ignition and
regulation is made by the switch and allows the possibility of disconnecting
the turbine (position 0), even with combustion in the equipment. In the same
way, if you want the turbine to operate, you must place the switch in position
1 (slow speed) or 2 (fast speed).
Connection
In the right side of the insert you will find the cable that connects
to the network. It is mandatory to not cut it in the entire length
because this section is useful when changes in the electrical
components are needed.
It is obligated the correct connection of the installation to earth connection.
The installation of the system might be done by skilled labour and qualified under the current rules.
WARNING!!
The insert (except Paris Series, Londres-T and Cairo Series) must be always connected to
electrical network in order to, in case of a high temperature, fans could start and dissipate the
heat to the room where it is installed or to any other adjacent room. The insert must never be
unplugged from the network when it is burning. In this case, the warranty of the insert shall
terminate.
The inserts are provided with connections for two ventilation additional outputs.
To install them, follow the next steps:
a.
Remove the close covers of the air outputs placed at the high of the sump.
b.
Set the connection collars on the hole or holes.
c.
Drill the wall or existent hood to pass and install the fireproof flexible tubes (diameter of 12 cm)
with their corresponding connection.
d.
Set the tubes with metallic clamps to the corresponding collars and grilles. Each pipe must not
exceed recommended channelling length and it must be insulated with insulated materials to
avoid noises and loss of heat.
e.
The grilles must be placed higher than 2 meters over the floor to avoid the heat air annoy the
people.
2.1
LONDRES AND LONDRES-T VISIÓN SERIES CENTRAL UNIT
L1
OFF
P1
External aspect and electrical connections
PRODUCT COMPOSITION
-
Switchboard
-
Cover Plate, Inserting box
-
Temperature Probe, Instructions
FUNCTIONING
ON/OFF:
The On/Off of the controller is made by pushing the button P1
The state OFF is signaled through the led L1
FUNCTIONING Modality
-
MANUAL: advice signal MAN
The fan is at the set speed independently by the Probe's temperature
-
AUTOMATIC: advice signal AUT
The Fan starts at the set up speed when the trmperature is higher than the setted Thermostat SET
-
PROPORTIONAL: advice signal PROP
The fan changes its speed according to the temperature in the range SET ÷ SET+DEL
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
MAN
L2
L3
AUTO
PROP
L4
L5
MENU
P2
P3
P4
CONNECTION TO
GROUND
INSTALLATION SUPPORT
CHASSIS OF THE
CONNECTION
TO GROUND
LINEA VENT.
230 Vac 230 Vac
32
220 V
L
N
FANS
THERMOSTAT
R 820 ohm
50 W
COMMUTADOR 2
POSITIONS
SONDA
FUSE
INSERTS