Operation goes into PROPORTIONAL mode with a delay of 10 seconds.
-
STANDBY FUNCTION
In the case that the device is OFF, if the probe temperature exceeds 100-120ºC, the device automatically switches to the on state.
-
PROBES DISPLAY
The display shows the value read by the probe.
-
If the reading of the probe is below the minimum range of the sensor, the message Lo is displayed.
-
If the probe reading is above the maximum range of the sensor, the message Hi is displayed.
Attention
-
Avoid coupling the probe cables with the power cables.
-
Install a bipolar switch in the power supply system according to the standards in force and with an opening distance from the contacts
of at least 3 mm per pole.
-
The installation and electrical connection of the device must be carried out by qualified personnel with the appropriate equipment.
-
Before making any connection, check that the mains is disconnected.
Main menu
It can be accessed by pressing the K2 key for 3 seconds.
-
The K2 key is used to scroll through the various parameters, indicated by the flashing of the corresponding LED.
-
With the keys K3 and K4 you can modify the value of the parameters.
-
Press key K2 to save the new value or wait 10 seconds.
-
Press key K1 to exit without saving.
Fan menu
Through this menu you can select the fan speed.
-
By pressing the keys K3 and K4 it is possible to display and modify the selected fan speed (LED flashes).
-
MANUAL MODE: the fan can be turned off by adjusting the speed P0, or select a speed from P1 (minimum speed) to P10 (maximum
speed).
-
AUTOMATIC MODE: the fan cannot be switched off, a speed can be selected from P1 (minimum speed) to P10 (maximum speed).
-
PROPORTIONAL MODE: the fan cannot be turned off and the speed cannot be adjusted; only the speed selected by the
thermoregulator can be displayed.
-
Press key K2 to store the new value or wait 5 seconds.
-
Press key K1 to exit without saving.
Installer menu
Access to this Menu is INSTALLER COMPETITION or QUALIFIED PERSONNEL, because the parameters indicated, if modified, may make the
product unsuitable for the application in use.
-
To access the MENU, press keys K2 and K4 at the same time for about 3 seconds.
-
To scroll through the parameter codes use keys K3 and K4.
-
To display the parameter value and enter the modification, press the K2 key.
-
To change the value press keys K3 and K4
-
To save the selected value, press the K2 key.
-
To exit without saving press the K1 key.
-
Press the K1 key again to exit the menu or wait 60 seconds.
Description
Air thermostat for fan activation
Air thermostat for safety
Air thermostat for alarm
Air thermostat for safety fan
Air thermostat for valve opening
Air thermostat for valve closure
Air thermostat for service output activation
Temperature delta for proportional operation
Hysteresis thermostat fan activation
Hysteresis thermostat for safety
Hysteresis thermostat for alarm
Hysteresis thermostat for fan safety
Hysteresis thermostat for valve opening
Hysteresis thermostat for valve closing
Hysteresis thermostat for activation of service output
Hysteresis room thermostat
Fan speed P01 (minimum)
Fan speed P09 (ninth)
P10 fan speed (maximum)
Air valve closing delay time
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
Cod.
Min
E01
30
E02
80
E03
100
E04
100
E05
20
E06
20
E07
20
E50
20
IE01
1
IE02
1
IE03
1
IE04
1
IE05
1
IE06
1
IE07
1
Ib01
0
UA01
20
UA09
80
UA10
100
t06
0
35
Set
Max
U.M.
45
100
100
140
120
180
135
180
30
140
80
140
50
180
40
100
2
40
2
40
2
40
2
40
2
40
2
40
2
40
1
20
1
100
1
100
1
100
10
120
ºC
ºC
ºC
ºC
ºC
ºC
ºC
ºC
ºC
ºC
ºC
ºC
ºC
ºC
ºC
ºC
%
%
%
min
INSERTS