- Keep the arm in position and wait for the acoustic confirmation signal.
- Return the measuring arm to the rest position. Automatically the machine will set up in
the EASY ALU balancing programmes (FSP programme).
- Perform a spin.
- At the end of the spin, if you want to change the balancing programme set automati-
cally by the machine (FSP), select the balancing programme icon
the ENTER button until the required programme is selected.
Applying balancing weights. (Fig. 17)
• Adhesive weights applied with the weight-holder device (if provided) and after modify-
ing the application position from 12 o'clock to CLIP in the "Adhesive Weight Application
Position" set-up menu.
- Select the plane where the first balancing weight is to be applied.
- Rotate the wheel until the central element of the corresponding position indicator
lights up.
If the weight to be applied is a conventional clip type (inner side in EASY ALU2), apply
it on the corresponding 12 o'clock position. If the weight to be applied is instead the
adhesive type and the weight-holder device is installed, proceed as follows:
- Centre it inside the cavity of the weight-holder terminal of the measuring arm (Fig.17
a, b), with the backing paper of the adhesive strip facing up. Remove the protection
(Fig. 17c) and turn the terminal so that the adhesive faces the internal surface of the
rim.
- Move the sensor until the two reference lines (green in colour) coincide in the relevant
windows on the screen.
- Turn the end of the measuring arm until the weight adhesive strip is in line with the
rim surface.
- Press the button (Fig.17d) to eject the weight and make it stick to the rim.
- Return the measuring arm to the rest position (Fig.17e).
a
- Repeat the operations to apply the second balancing weight.
- Perform a test wheel spin to check the balancing accuracy.
94
b
d
Operator's manual MT 3600 - MT 3600 C Up
c
e
and press
17