WARNING:
The list of the configuration programmes can be displayed as follows:
- Select the utility and configuration programmes
- Select the configuration programmes
- Select view other icons
Calibrate when detecting that the setting condition is out-of-tolerance or when the ma-
chine so requires as the E 1 message is displayed.
Calibrate as follows:
1.
select the sensitivity calibration icon
;
2.
fit a wheel of average dimensions (diameter
no less than 14") on the wheel balancer with
only a small unbalance;
3.
perform a spin;
4.
at the end of the spin, fix the calibration
weight supplied with the machine on the
swinging unit bell as indicated in figure 23;
5.
perform a second spin;
6
at the end of the spin, change the posi-
tion of the calibration weight on the shaft
assembly bell as indicated in figure 23a;
7.
perform a third spin. This last calibration
phase includes the execution of three con-
secutive spins in automatic mode.
If the calibration has been successful, a permis-
sion acoustic signal goes off at the end of the
spin; otherwise, the E 2 message is temporarily
displayed.
Notes:
- Once the procedure is finished, remove the
calibration weight;
- Press the
calibration procedure at any time;
- This calibration is valid for any kind of wheel.
116
icon.
Sensitivity Calibration
button to interrupt the
Operator's manual MT 3600 - MT 3600 C Up
icon;
icon;
in the configuration program menu
23
23a