LED1. In this configuration, the light turns on when:
- at the end of a spin cycle if residual unbalances are present for 30 seconds;
- in CP (centred position) for an additional 30 seconds.
LED2. In this configuration, the light turns on in the conditions indicated for the LED1
programme and, in addition, also in the following conditions:
- when the internal sensor is extracted. When the sensor returns to the rest position,
the light turns off;
- during the entire measurement cycle with all balancing programmes;
- during the Hidden Weight programme when selecting the two planes behind the
spokes.
LEDOFF: deactivated
Press the Enter
bled if it is in the following configuration:
- press
It is possible to activate or deactivate the laser when present on the machine.
After the list of the setting programmes is displayed:
- Select the LASER activation/deactivation icon
- Two icons will appear on the display that represent the possible LASER modes, as
shown below:
LASER OFF.
LASER ON. In this configuration, the laser turns on in the following cases:
for the manual application of all adhesive weights.
IMPORTANT:
If the operator selected the adhesive weight application configuration using a CLIP, in
the Alu1 or Alu2 balancing programmes the laser will not be activated as the weight will
be applied using the weight holder
In the Hidden Weight programme, the selection of the two new positions behind the
spokes is done in the 6 o'clock position using the laser line.
Press the Enter
The selected icon is enabled if it is in the following configuration:
- Press
Operator's manual MT 3600 - MT 3600 C Up
button to select the desired mode. The selected icon is ena-
to confirm the selection made and exit the function.
LASER activation/deactivation
button to select the icon desired.
to confirm the selection made and exit the function.
115