The automatic measuring devices are not working
The sensors were not in the rest position when switching on the machine and the Enter
button
was selected, disabling control of the automatic sensors.
➥ Return the sensor to its correct position.
The automatic arm laser line does not work (if present)
Battery to replace, proceed as follows:
- Remove the four screws in the lever (A,
Fig.25) and then remove the plastic cover
(B, Fig.25)
- Remove the card (C, Fig.25) present
inside it
- Replace the battery in the card with a
new 3V CR2450;
- Proceed with the assembly of the lever
in the opposite direction to disassembly.
CAUTION
Pay attention to the positioning of the ca-
bles inside the recess of the lever to avoid accidentally damaging the cable itself when
closing the plastic casing.
If the laser line does not work with the new battery, call for technical assistance.
Pressing the START key the wheel does not spin (the machine
Contact the technical support centre.
The wheel balancer provides unsteady unbalance values
The machine was jolted during the spin.
➥ Repeat the spin, taking care not to disturb the machine while measuring is in progress.
The machine does not firmly rest on the floor.
➥ Make sure that the floor support is firm
The wheel is not locked correctly.
➥ Tighten the securing ring nut correctly.
Several spins are to be performed to balance the wheel
The machine was jolted during the spin.
➥ Repeat the spin, taking care not to disturb the machine while measuring is in progress.
The machine does not firmly rest on the floor.
➥ Make sure that the floor support is firm.
The wheel is not locked correctly.
➥ Tighten the securing ring nut correctly.