5 | Fitting the collet chuck
6. Place the collet chuck with the base plate in the correct position on the
machine table (align if necessary) and firmly tighten with the holding
screws (provisionally 5 Nm).
7. Tighten the holding screws with the specified tightening torque (see
Checking the Tightness of Screw Connections [} 87]).
ü The collet chuck is mounted with a base plate.
5.6
Fitting the insert (workpiece stop and protective sleeve)
1 Threaded pin
2 Workpiece stop
1. Loosen the three threaded pins (1) from the flange at the side.
2. Insert the insert (protective sleeve (3) with workpiece stop (2)) from the
front into the basic body.
3. Secure the insert with the three threaded pins (1).
76 / 240
Damage due to infiltrating swarf.
Infiltrating swarf leads to increased wear and malfunction of the
collet chuck.
Ø Never operate the collet chuck without an insert.
NOTICE
1
3 Protective sleeve
2
3
1242467 CAPTIS-M