en
Chapter 9
Fig. 11: Derating curve for
the contact currents on the
safety contacts
76
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
Technical specifications
Safety-related parameters
All these data are based on an ambient temperature of +40 °C.
Safety Integrity Level
2)
SIL claim limit
2)
Category
Performance Level
2)
T
(mission time)
M
MTTF
d
MTTF
t
cycle
Hardware fault tolerance (HFT)
SFF
PFHd (mean probability of a
dangerous failure per hour)
B
10d
Derating curve for the contact currents
2)
For detailed information on the safety design of your machine or system, please contact your local SICK
representative.
Minimum
Typical
SIL3 (IEC 61508)
SILCL3 (EN 62 0 61)
Category 4 (EN ISO 13 8 49-1)
PL e (EN ISO 13 8 49-1)
20 years (EN ISO 13849)
93 years
181800 h (20.8 years)
28.8 × 10
3
s/cycle or 1 cycle/8 h
1
99.7%
41 × 10
–9
B
= 500000 cycles
10d
(Usage category according to IEC 60947-5-1:
DC13)
8014608/1DS0/2022-02-16
Operating instructions
MOC3ZA
Maximum
Subject to change without notice