Installation

• Installation (removal) of the electric chain hoist must be carried out by special installer or by personnel with expertise.
Consult with the sales shop or KITO for installation, or consign the installation work to special installer or personnel with expertise.
• Do not install the electric chain hoist at a place exposed to rain or water always or the place different from the
Prohibited
Operational Environment (P18).
• Do not install the electric chain hoist in the motion space of other trolley or any other moving equipment (facility).
• Do not use the electric chain hoist contacting with other object, or being fixed.
Failure to comply with these instructions may result in death or serious injury.
• When installing or removing the electric chain hoist, follow the instructions in Owner's Manual.
• Carry out the work for grounding (earthing) and installation of earth leakage breaker with
higher harmonic countermeasures.
Mandatory
• When the installation is completed, carry out "Check after Installation". (See P61)
• Connect the power after all installation works have been completed and just before the
oparation check.
• Mount the stopper at the both ends of the travel rail for trolley. <Fig. A>
• Make sure that the strength of the structure is sufficient to install the electric chain hoist.
• Carry out the installation work after securing the stable hoothold.
• When not using the KITO Standard Trolley and use the Electric Chain Hoist incorporated
as part of your travel device, make sure to contact KITO for precautions.
Failure to comply with these instructions may result in death or serious injury.
• Connect the Power Cable to the power of rated voltage.
Failure to comply with this instruction causes bodily injury or loss of property.
Mandatory

■ Connecting Power and Power Cable

When connecting the Power Cable to the power, connect the cable in accordance
with the following instructions.
● Connect the electric chain hoist to the power through a breaker.
● Connect the electric chain hoist in the correct phase.
(When 'Check after Installation (P61)' is completed, carry out the operation check for
the correct phase.)
● Earth wire is a green colored covered cable with yellow line. Carry out Class D
earthing work.
● Use correct breaker and Power Cable referring to Checking the Power and the Power
Cable (P53) for the breaker capacity, Power Cable length and its size.

■ Installing the Hook Suspended Type (hoist only)

■Checking Installation Method and Place
When using an electric chain hoist suspended (as a single unit) without combination with a trolley, make
sure that the Hook Latch of the Top Hook closes securely.
• Make sure that the Top Hook and body can swing freely. Do not restrain the Top Hook and body during use.
Mandatory
• Do not install and use the electric chain hoist upside down.
Failure to comply with these instructions may result in death or serious injury.
DANGER
CAUTION
DANGER
Travel rail
Stopper
A
L1
L2
L3
R-
S-
T-
phase
phase
phase
Breaker