Symptom
Cause
Electromagnetic
Rusting
Brake does not
operate.
Breakage of rectifier Measure the resistance of the rectifier
Too long (or short)
Abrasion of brake
stopping distance
lining
(stopping distance
may change slightly
depending on the
temperature.)
Louder operating
Abrasion of brake
sounds
lining
Remedy
When the Brake is rusted shut, replace
the brake unit as a whole.
with circuit tester.
Anode terminal : Negative probe of the
circuit tester
Cathode terminal : Positive probe of the
circuit tester (measure
the resistance in kΩ
range)
When the resistance is almost zero, the
rectifier is normal.
In other cases, replace the rectifier.
Measure the brake gap. If the gap
exceeds the service limit, replace the
electromagnetic brake unit as a whole
(See P79.)
Measure the brake gap. If the gap
exceeds the service limit, replace the
electromagnetic brake unit as a whole
(See P79.)
Main factor
Countermeasure
Wrong assembling of
Assemble the brake
packings
cover packings and V ring
securely.
Replace the packing if
deteriorated.
Leaving the electric
Operate the electric chain
chain hoist in an
hoist regularly.
environment with rich
moisture
Dew condensation
Pay attention to the use
in an environment where
the ambient temperature
changes rapidly.
Over current due to
Operate the electric chain
over voltage or low
hoist at the rated voltage.
voltage
Excessive inching or
Do not perform excessive
plugging operation
operation.
(consecutive
impression of start
rush current)
Over current due to
Use the electric chain hoist
over load
with a load less than the
capacity.
Operation exceeding
Check the short time rating
short time rating or
and intermittent rating.
intermittent rating
Use the electric chain hoist
within these ratings.
Over current due to
The electric chain hoist
open phase operation
cannot lift a load in open
phase operation. When any
abnormality is observed,
stop the operation
immediately and check
the cause of open phase
operation.
Excessive inching
Do not perform excessive
operation
operation.
Excessive inching
Do not perform excessive
operation
operation.
3