Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

V750 IE
4.3.11.

TIMING DATA

Intake:
-
opens 18° before T.D.C.;
-
closes 50° after B.D.C.
Exhaust:
-
opens 53° before B.D.C.;
-
closes 15° after T.D.C.
Valves clearance for timing check 1 mm (0,039).
Valves clearance for operation:
-
intake
0.15 mm (0,0059);;
-
exhaust
0.20 mm (0,0079);.