Turn clockwise until contact between rod and rocker
arm is reached and on goniometer check intake valve
advance with respect to top dead centre.
Continue to turn until rod is free, read the value
representing retard of the valve closing with respect to
bottom dead centre.
Repeat operation for the other valves.
Adjust tappet clearance to clearance prescribed.