8.11.4 Synchronising the unit with the
camera module
To synchronise the unit with the camera module:
• Adjust the left illuminator (MASTER):
• Lighting threshold: Set the value to the
minimum (8.11.7 LED illuminator switching on
threshold adjustment, page 32).
• Infrared power: Set the value as needed (8.11.8
LED illuminator power adjustment, page 32).
• Adjustment of the the illuminator on the right
(SLAVE):
• Lighting threshold: Set the value to the
maximum (8.11.7 LED illuminator switching on
threshold adjustment, page 32).
• Infrared power: Set the value to the minimum (
8.11.8 LED illuminator power adjustment, page 
32).
• Set the Camera value under IR Probe in the Main
menu > Block camera > Advanced > Infrared menu
(10.1.8.10 Advanced Setting Menu (Infrared), page 
50).
INFRARED
------------------------
1>IR PROBE
3 NIGHT LEVEL
4 NIGHT DELAY
5 DAY LEVEL
6 DAY DELAY
Fig. 49
30
: CAMERA
:
5
:
5
:
20
:
30
8.11.5 Synchronising the unit with the
LED illuminators
To synchronise the unit with the LED illuminators it is
necessary to:
• Adjust the left illuminator (MASTER):
• Lighting threshold: Set the value to the
minimum (8.11.7 LED illuminator switching on
threshold adjustment, page 32).
• Infrared power: Set the value as needed (8.11.8
LED illuminator power adjustment, page 32).
• Adjustment of the the illuminator on the right
(SLAVE):
• Lighting threshold: Set the value to the
maximum (8.11.7 LED illuminator switching on
threshold adjustment, page 32).
• Infrared power: Set the value to the minimum (
8.11.8 LED illuminator power adjustment, page 
32).
• For unit fitted with integrated module, set the
Int. value under IR Probe, in the Infrared menu (
10.1.8.10 Advanced Setting Menu (Infrared), page 
50).
INFRARED
------------------------
1>IR PROBE
Fig. 50
:
INT.