A display such as that shown
PROBLEM
below appears instead of the
footage:
INFO
------------------------
Device ID: 00001
Type
: Rs485 only Rx
Baud Rate: 19200-8N1
Protocol : PELCO-D
Net Board: Fw05.01 Hw00
Mpp Board: Fw05.01 Hw00
Config.
: 001
P.C.
: UPT1SMSA005C
S.N.
: 0000000000000
Upgrade
: NET BOARD
Programming dip-switch on.
CAUSE
SOLUTION
Turn off the P&T. Lower the firmware
update dip-switch lever (8.12.2 DIP1
configuration, page 33). Turn the
unit on again.
Error E1:PATROL
PROBLEM
CONFIGURATION.
The presets have not been saved.
CAUSE
The presets have not been enabled.
SOLUTION
Save one or more presets (12.2
Saving a Preset, page 60). Update
the Patrol configuration menu (
10.1.9.6 Patrol Menu, page 54).
Enable presets (10.1.9.4 Preset Menu
(Edit Preset), page 53).
66
Error E2:AUTOPAN
PROBLEM
CONFIGURATION.
The two presets used as limits have
CAUSE
not been saved.
The two presets used as limits have
not been enabled.
SOLUTION
Save two presets (12.2 Saving
a Preset, page 60). Update the
autopan configuration menu (
10.1.9.7 Autopan Menu, page 54).
Enable presets (10.1.9.4 Preset Menu
(Edit Preset), page 53).
Error E3:WASHER DISABLED
PROBLEM
or error E4:WASHER PRST
DISABLED.
Washing system not enabled.
CAUSE
SOLUTION
Enable the washer system (10.1.11.2
Washer Menu, page 57).
Error PRESET XXX NOT
PROBLEM
ENABLED.
Restore an unsaved preset
CAUSE
Restore a non-enabled preset
SOLUTION
Save the preset using the relative
control (12.2 Saving a Preset, page 
60).
Enable preset (10.1.9.4 Preset Menu
(Edit Preset), page 53).
MNVCUPTDMB_2104_EN