17.5 Communications

RS232 interface for PC control and firmware update
2-ports RS485: daisy chain configuration or RS232
Addressable through dip-switch up 255 units

17.6 Protocols

Configuration of telemetry protocol parameters
through dip-switch
AMERICAN DYNAMICS, PANASONIC, PELCO D,
VIDEOTEC MACRO, VISTA
AMERICAN DYNAMICS, PANASONIC, PELCO, VISTA are registered
trademarks.
The product may be interfaced with devices not manufactured by
VIDEOTEC. It is possible that the interface protocols have changed or
are in a different configuration from earlier tested units by VIDEOTEC.
VIDEOTEC recommends a test prior to installation. VIDEOTEC will
not be liable for any installation costs or lost revenues in the event a
compatibility problem will occur.
MNVCUPTDMB_2104_EN

17.7 Environment

Indoor/Outdoor
Operating temperature
• With heater: from -20°C (-4°F) up to +60°C (140°F)
• With reinforced heater: from -30°C (-22°F ) up to
+60°C (140°F)
Wind resistance (without LED illuminators):
• Operational: up to 160km/h
• Stationary: up to 210km/h
Surge immunity: up to 2kV line to line, up to 4kV line
to earth (Class 4)

17.8 Certifications

Electrical safety (CE): EN60950-1, IEC60950-1,
EN62368-1, IEC62368-1
Electromagnetic compatibility (CE): EN50130-4,
EN55022 (Class A), EN610000-6-3, FCC Part 15 (Class
B)
Outdoor installation (CE): EN60950-22, IEC60950-22
Photobiological safety (CE): EN62471 (LED
illuminators)
IP protection degree: EN60529 (IP66)
Salty fog resistance: EN50130-5, EN60068-2-52
UL certification: cULus Listed (TYPE 4X) (not for
thermal cameras version)
EAC certification