8.5.3 Connection of the alarm inputs, of
the twilight switch and of the relays
CAUTION! TNV-1 installation type. The
installation is type TNV-1, do not connect it
to SELV circuits.
CAUTION! In order to reduce the risk of fire,
only use UL Listed or CSA certified cables
sizes greater than or equal to 0.13mm² (26
AWG).
Standard version
AL1
AL3
COM
AL2
AL4
+
Vdc
V
Fig. 33
Alarm input.
O1 C1
V
Fig. 34
Relay.
CONNECTION OF THE ALARM INPUTS AND RELAYS
Terminals
Description
AL1, AL2,
Voltage-controlled alarm inputs referred to
AL3, AL4 e
the COM shared terminal
COM
F1-F2
Reserved for future use
O1-C1 e
Clean output contacts, can be activated by
O2-C2
alarm or by user control
Tab. 10
Standard version.
24
02 C2
V
Version with LED illuminators
AL1 AL2 LNO
AGND
+
Vdc
V
Fig. 35
Alarm inputs and twilight switch..
O1 C1
V
Fig. 36
Relay.
CONNECTION OF THE ALARM INPUTS, OF THE
TWILIGHT SWITCH AND OF THE RELAYS
AL1, AL2 e
Voltage-controlled alarm inputs referred to
AGND
the AGND shared terminal
F1-F2
Reserved for future use
LNO e AGND
Light sensitive switch (dry contact)
O1-C1 e
Clean output contacts, can be activated by
O2-C2
alarm or by user control
Tab. 11
Version with LED illuminators.