7 Assembly

7.1 How to open the housing

Loosen the 2 screws on the side, turn the cover and
the upper half of the body about the opening hinge
axis.
Fig. 8
After installation and wiring, close the
product again.
14

7.1.1 How to install the camera

It is necessary to insulate the camera body
from the attachment slide in order to
prevent interference with the video signal.
Take out the inner support slide (01) loosening the
fastening screws (02). Fasten the camera with the 1/4"
screw (03). Adjust the internal slide so that the lens
and camera are positioned correctly.
Fasten down the adjustable slide in the correct
position using the appropriate screws. When
positioning the camera use also the spacers supplied
for this purpose (04).
02
04
01
03
Fig. 9
Reposition the internal slide and tighten the screws
that had been loosened previously.

7.1.1.1 Cameras features

The correct operation of the equipment,
within the temperature range indicated, is
guaranteed only if you use camera and lens
with temperature limits equal to at least
-10°C and + 60°C.
• The power supply voltage of the camera must be
12Vdc.
• The maximum absorbed current by the camera
must be less than 800mA.
• The camera output video signal must be of the
composite type with amplitude 1Vpp (negative
sync).
MNVCUPTDMB_2104_EN