AD USTING T E WATER PRESSURE
2. Turn on water supply valve (B).
4. Turn the cooking chamber water intake screw
(D) to bring the pressure reading on pressure
gauge (E) to 14.5 psi.
If the water pressure is too low, install a device
to increase the pressure.
5. Retighten ring nut (C).
6. Replace side panel (A)
screws.
7. Turn water supply valve (B)
when the operation is complete.
E
C
(A).
(C).
tighten all
D
A
Combination Oven Installation and Operation Manual
Section 4
Handling and Installation
B
25