6.7.
electrical data
6.7.1.
electrical data without bus control 24 V dc
Connections:
Pilot valve:
Supply voltage
Power input
Output:
Display:
6.7.2.
electrical data with as interface bus control
Connections:
Profile:
Electrical supply voltage:
Outputs
Max. switching capacity:
Watchdog function:
Max. power consumption:
Power consumption input during
normal operation:
(after current reduction;
valve + 1 end position reached)
14
Circular plug-in connector (M12 x 1, 8-pole)
24 V DC ± 10% - max. residual ripple 10 %
max. 1 W
max. 100 mA per output
max. 20 mA per illustrated illuminated display (LED)
Circular plug-in connector (M12 x 1, 4-pole)
S-B.A.E. (A/B slave, max. 62 slaves/master)
29.5 V – 31.6 V DC (according to specification)
1 W via AS-Interface
integrated
120 mA
90 mA
english
Type 8695