Danger!
risk of injury from high pressure!
• Before dismounting pneumatic lines and valves, turn off the pressure and vent the lines.
Procedure:
→
Clamp valve body in a holding device (only required if the process valve has not yet been installed).
→
Control function A: Open process valve.
Hexagon
Figure 14:
Rotating the actuator module
→
Using a suitable open-end wrench, counter the wrench flat on the pipe.
→
Place suitable open-end wrench on the hexagon of the actuator.
Warning!
risk of injury from discharge of medium and pressure!
If the direction of rotation is wrong, the body interface may become detached.
• Rotate the actuator module counter-clockwise only! (see "Figure 15")
→
Rotate counter-clockwise (as seen from below) to bring the actuator module into the required position.
Figure 15:
Rotating with open-end wrench
24
Nipple
Series 21xx
english
Actuator module
Series 20xx
Open-end wrench
Type 8695
Installation
Hexagon
Nipple