15.
disasseMBly
15.1. safety instructions
Danger!
risk of injury from high pressure!
• Before dismounting pneumatic lines and valves, turn off the pressure and vent the lines.
risk of electric shock!
• Before reaching into the device or the equipment, switch off the power supply and secure to prevent
reactivation!
• Observe applicable accident prevention and safety regulations for electrical equipment!
Warning!
risk of injury from improper disassembly!
• Disassembly may be carried out by authorized technicians only and with the appropriate tools!
risk of injury from unintentional activation of the system and an uncontrolled restart!
• Secure system from unintentional activation.
• Following disassembly, ensure a controlled restart.
15.2. disassembly the control head
Procedure:
1. Pneumatic connection
Danger!
risk of injury from high pressure!
• Before dismounting lines and valves, turn off the pressure and vent the lines.
→
Loosen the pneumatic connection.
→
20xx series:
Loosen the pneumatic connection to the actuator.
40
english
Type 8695
Disassembly