Preliminary Checks; Installation Environment; Condition Of The Gate To Be Motorised; Risk Prevention - SOMFY ELIXO SMART io Manuel D'installation

Masquer les pouces Voir aussi pour ELIXO SMART io:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

io Elixo Smart
WARNING
Any use of this product outside the field of application
described in these instructions is prohibited (see "Field of
application" paragraph in the installation manual).
The use of any accessory or any component not
recommended by Somfy is prohibited, on safety grounds.
Any failure to comply with the instructions given in this
manual shall exempt Somfy from all liability, and invalidate
the SOMFY warranty.
If in any doubt when installing the drive, or to obtain additional
information, visit the website www.somfy.com.
The instructions may be modified if and when there is a change
in the standards or the drive.

1.3. Preliminary checks

1.3.1. Installation environment

NB
Do not spray water onto the drive.
Do not install the drive in an explosive environment.
Check that the temperature range marked on the drive is
suited to the installation location.

1.3.2. Condition of the gate to be motorised

Do not motorise a gate which is in poor working order or has
been incorrectly installed.
Before installing the drive, check that:
• the gate is in good mechanical condition
• the gate is stable, irrespective of its position
• the gate holding the rack must be sufficiently robust.
• the gate can be opened and closed properly using a force
of less than 150 N.

1.4. Risk prevention

WARNING
Risk prevention - sliding gate drive for residential
use
Ensure that any danger zones (crushing, cutting, trapping)
between the driven section and the surrounding fixed
sections created by the opening of the driven section are
prevented, or indicated on the installation.
Permanently affix the crushing warning labels near any
fixed control devices or so that they are clearly visible.
Copyright © 2018 SOMFY ACTIVITES SA. All rights reserved.
Risk zones: what elimination measures can be taken?
Zone 1
Zone 4
RISK
SOLUTION
ZONE 1
Obstacle detection built into the
drive. Obstacle detection must be
Risk of crushing
confirmed as being compliant with
when closing
Annex A of standard EN 12 453.
For operation with automatic clos-
ing, install photoelectric cells.
ZONE 2
Obstacle detection built into the
drive. Obstacle detection must be
Risk of trapping
confirmed as being compliant with
and cutting on the
Annex A of standard EN 12 453.
surface of the door
Eliminate any gap ≥ 20 mm
ZONE 3
Obstacle detection built into the
drive. Obstacle detection must be
Risk of crushing
confirmed as being compliant with
with an adjoining
Annex A of standard EN 12 453.
fixed section upon
opening
Protection via safety distances (see
figure 1)
ZONE 4
Eliminate all sharp edges on the
guide rails.
Risk of trapping and
crushing between
Eliminate any gap ≥ 8 mm between
the roller rails and
the rails and the bearings.
bearings
ZONE 5
Eliminate any gap ≥ 8 mm between
the pinion and the rack.
Risk of movement
force and crushing
at the pinion/rack
connection
No protection is required if the gate has continuous control
or if the danger zone is more than 2.5 m above ground or any
other permanent access level.
Zone 3
Zone 2
Zone 5
EN
2

Publicité

Table des Matières
loading

Table des Matières