12.1. Connection to the solar power supply

Connect the solar power supply cable to the "BATT" terminal on the mo-
tor's electronic unit.
2
1
2
1
3
3

12.2. Advice for use

If the gate is barred, we would suggest you protect the access to the arm
from the outside of the property.
In order to limit the energy consumption of your gate motor, we recom-
mend:
• the gate be closed to optimise the battery charge,
• the gate not be le open for more than 2 days,
• to activate automatic closing of the gate.
13. DIAGNOSTICS
SHOOTING
Attention
Power the installation off during cleaning or other maintenance
operations.
DIAGNOSTICS
The motors are
The remote
not responding
control range is
to remote con-
reduced
trol commands
Remote control
not stored
1 or 2 motors
unlocked
The control
Motor not
=
unit's
powered
=
indicator light
Outdoor lighting
is off
very low = motor
on standby
The control
=
unit's
=
indicator light
flashes:
Copyright © 2017 SOMFY ACTIVITES SA. All rights reserved.
AND
TROUBLE
TROUBLESHOOTING
- Check the remote control battery.
- Check the electronic unit aerial.
- Check that there are no outside
elements that are interfering with
the radio signal (electricity pylon,
metal reinforced walls, etc.). If
this is the case, fit an external
aerial.
Store the remote control.
Lock the motors.
- Check the power supply.
- Check the power supply cable.
Increase the light around the elec-
tronic unit (e.g. using a torch) in
order to perform the settings (see
Ambient light detector below)
DIAGNOSTICS
1 pulse
Operation
using the backup
battery
2 pulses
Motor awaiting
gate travel
self-program-
ming
3 pulses
Cell fault:
- Cells blocked
- Cells mis-
aligned
- Cells incorrect-
ly wired
- Cells missing/
disconnected
4 pulses
Short circuit on
the electronic
unit BUS output
(terminals 3-4)
5 pulses
Electronics
thermal safety
activated
6 pulses
Short circuit on
the control unit's
24 V output
(terminals 5-6)
Short circuit
of orange light
(terminals 7-8)
on the control
unit
Motor short
circuit
Automatic clos-
Photoelec-
ing mode is not
tric cells not
activated
installed
(the
indicator light
stays off).
TROUBLESHOOTING
Check the mains power supply.
Launch gate travel auto-program-
ming.
Remove the obstacle blocking the
cells.
Correct their alignment (see in-
structions supplied with the cells).
Wire the cells in accordance with
the instructions.
- Check that the cells are correctly
connected.
- If you have deliberately discon-
nected the cells and your gate is
operating in automatic closing
mode, deactivate automatic
closing mode.
Check the accessories connected
to the electronic unit's BUS output.
Allow the electronics to cool down
until the
indicator light comes
=
=
on continuously.
Check the accessory connected to
the electronic unit's 24 V output.
Check the wiring of the orange
light.
Check the motor wiring.
Install the cells (see instructions
supplied with the cells for instal-
lation).