Installation 1; Unlock The Motor; Installing The Motor; Fastening The Motor To The Ground - SOMFY FREEVIA LINE Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

1.1 Unlock the motor

1.2 Installing the motor

Fastening the motor
to the ground
1
• Position the installation
c
template
on the
ground and drill 4
holes using a drill bit (Ø
12 mm) suitable for the
type of ground.
Check that the motor is level.
Position the motor's handle
The pinion is freed.
The motor is unlocked.
2
• Insert the plugs. Tighten the studs.
• Tighten 4 nuts and 4 washers.
• Remove the motor cover.
• Position the motor on the studs: ensure that
the bracket (base of
the motor) is no more
than 25 mm above the
ground. The
recommended space
is between 20 and
25 mm.
• Once the motor is
positioned at the right height in relation
to the ground, fix it in place using the 4
washers and 4 nuts.
EN - FREEVIA LINE installation and operating guide - SOMFY

INSTALLATION 1

12
17
T25
3
• Position the pre-drilled
grommet in the
opening provided for
the cable feed.
9

Publicité

Table des Matières
loading

Table des Matières