Presentation Of The Control Electronics - SOMFY FREEVIA LINE Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Presentation of the control electronics

Mark
Designation
A
Button
B
RADIO
indicator light
C
Indicator light
D
Indicator light
E
Indicator light
P1
F
RESET
indicator light
G
Indicator light
4
EN - FREEVIA LINE installation and operating guide - SOMFY
G
F
E
D
C
Function
Self-learning launch
Reactivation of the control electronics
Lights up each time the control electronics receive a radio command
Lights up during activation/deactivation of the pedestrian opening
On
automatic closure of the gate is activated.
OFF
automatic closure of the gate is not activated.
Flashing
the "automatic closure" parameter is selected
OFF
the gate operates at standard speed
Slowly flashing
the gate operates at slow speed
Flashing
the gate "speed" parameter is selected
On
the settings alone or the settings and the radio
control points are deleted
Flashing
the settings and radio control points deletion
function is selected
On
the motor functions correctly - the control
electronics are reactivated
OFF
the motor functions correctly - the control
electronics are on standby
Flashing
see diagnostic page 32