stallation on a sliding gate, for residential use as defined in
standard EN 60335-2-103, with which it complies. The main
purpose of these instructions is to satisfy the requirements
of the aforementioned standard and to ensure the safety of
equipment and persons.
WARNING
Any use of this product outside the field of application
described in this guide is prohibited (see "Field of appli-
cation" paragraph in the installation manual).
The use of any accessory or any component not rec-
ommended by Somfy is prohibited, on personal safety
grounds.
Somfy cannot be held liable for any damage resulting from
failure to follow the instructions in this manual.
If in any doubt when installing the motorisation, or to obtain
additional information, visit the website www.somfy.com.
These instructions may be modified in the event of a change
to the standards or the motorisation.

1.3. Preliminary checks

1.3.1. Installation environment

ATTENTION
Do not spray water onto the motorisation.
Do not install the motorisation in an explosive environ-
ment.
Check that the temperature range marked on the mo-
torisation is suited to the installation location.

1.3.2. Condition of the gate to be motorised

Before installing the motorisation, check that:
• the gate is in good mechanical condition,
• the gate is stable regardless of its position,
• the gate holding the rack must be sufficiently robust,
• the gate can be opened and closed properly using a force
of less than 150 N.

1.4. Risk prevention

WARNING
Ensure that any danger zones (crushing, cutting, trap-
ping) between the driven section and the surrounding
fixed sections created by the opening of the driven sec-
tion are prevented, or indicated on the installation.
Permanently affix the crushing warning labels so that
they are clearly visible, or near any fixed control devices.
Copyright © 2017 SOMFY ACTIVITES SA. All rights reserved.
Zone 1
Zone 4
Risk zones: what elimination measures should be taken?
RISK
SOLUTION
ZONE 1
Obstacle detection built into the
motorisation. Obstacle detection
Risk of crushing
must be confirmed as being compli-
when closing
ant with Annex A of standard EN 12
453.
For operation with automatic clos-
ing, install photoelectric cells.
ZONE 2
Obstacle detection built into the
motorisation. Obstacle detection
Risk of trapping and
must be confirmed as being compli-
cutting on the sur-
ant with Annex A of standard EN 12
face of the door
453.
Eliminate any gap ≥ 20 mm
ZONE 3
Obstacle detection built into the
motorisation. Obstacle detection
Risk of crushing
must be confirmed as being compli-
with an adjoining
ant with Annex A of standard EN 12
fixed section upon
453.
opening
Protection via safety distances (see
figure 1)
ZONE 4
Eliminate all sharp edges on the
guide rails.
Risk of trapping and
crushing between
Eliminate any gap ≥ 8 mm between
the roller rails and
the rails and the bearings.
bearings
ZONE 5
Eliminate any gap ≥ 8 mm between
the pinion and the rack.
Risk of catching and
crushing at the pin-
ion/rack connection
No protection is required if the gate has hold-down control
or if the danger zone is more than 2.5 m above ground or any
other permanent access level.
Zone 3
Zone 2
Zone 5